GAS REQUIREMENTS

Instructions

Gas Dryers

 

 

 

 

NOTE : The gas service to a gas dryer must conform

 

with the local codes and ordinances or, in the absence

 

of local codes and ordinances, with the latest edition

Safety

of the National Fuel Gas Code ANSI Z223.1/NFPA

54 or the CAN/CGA-B149, National Gas Installation

 

 

Code.

 

 

L.P (Liquefied Petroleum) Gas, 2,500 Btu/ft3 (93.1

 

MJ/m3), service must be supplied at 10

1.5 in. water

Instructions

column pressure.

 

 

 

 

NOTE : DO NOT connect the dryer to L.P. Gas

Installation

Service without converting the gas valve.

number.

 

 

L.P. gas conversion:

 

 

In U.S.- Conversion must be made by a qualified

 

technician.

 

 

See gas valve burner base for gas conversion kit part

 

In Canada- Conversion must be made by a licensed

Instruction

system by closing its individual manual shut-off valve

 

technician. Contact your local service

branch if you

 

require further assistance.

 

 

The dryer must be isolated from the gas supply piping

Operating

during any pressure testing of the gas supply piping

system at test presure equal to or less than 1/2 psi (3.45

 

 

kPa).

 

 

NOTE : When connecting to a gas line, an equipment

 

shutoff valve must be installed within 6 feet (1.8m) of

Tips

the dryer. An 1/8 in. N.P.T. pipe plug must be

installed as shown. Refer to Fig

 

Troubleshooting

 

Supply line requirements:

 

 

 

 

Provide a rigid gas supply line to the dryer location.

 

In U.S.- An individual manual shutoff valve must be

 

installed within 1.8m (6 feet) of the dryer in accordance

 

with the National Fuel Gas Code ANSI Z223.1*.

 

In Canada- An individual manual shutoff valve must be

 

installed in accordance with the B-149 installation codes,

Customer Service

CAN/CGA B-149.1 and B-149.2*.

 

 

 

 

 

 

When a rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8- inch approved tubing may be used for lengths under 6.1 m (20 feet). For lengths over 6.1m (20 feet), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used.

WARNING

To reduce the risk of gas leaks, fire or explosion:

The dryer must be connected to the type of gas as shown on the nameplate located in the door recess.

Use a new flexible stainless steel connector.

Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads.

Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent a gas valve contamination.

Do not use an open flame to check for gas leaks. Use a non-corrosive leak detection fluid.

Any dis-assembly requiring the use of tools must be performed by an authorized qualified service person.