INSTALLING THE DRYER

Installation Instructions Safety Instructions

Step 3 : Connect Gas Supply Pipe (Gas Dryer ONLY)

For further assistance, refer to section on Gas

Requirements.

1.Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8” N.P.T. gas connection.

2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe thread when removing the cap.

3.Connect to gas supply pipe using a new flexible stainless steel connector.

4.Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid.

5.For L.P. (Liquefied Petroleum) gas connection, refer to section on Gas Requirements.

Customer Service Troubleshooting Tips Operating Instruction

1

2

5

3

4

1

New Stainless Steel Flexible Connector -

4

Black Iron Pipe

 

Use only if allowed by local codes (Use

 

Shorter than 20’ (6.1 m) - Use 3/8” pipe

 

Design A.G.A. Certified Connector)

 

 

 

Longer than 20’ (6.1 m) - Use 1/2” pipe

2

1/8” N.P.T. Pipe Plug (for checking inlet

 

5

3/8” N.P.T. Gas Connection

 

gas pressure)

3Equipment Shut-Off Valve-Installed within 6’ (1.8 m) of dryer

8

Page 8
Image 8
LG Electronics D2511W, D5932W, D2532W, D5911W, DLE2511W manual Connect Gas Supply Pipe Gas Dryer only, Requirements