EXHAUST REQUIREMENTS

Customer Service Troubleshooting Tips Operating Instruction Installation Instructions Safety Instructions

Number of 90°

 

 

 

Weather Hood Type

 

 

 

 

 

 

 

Elbows

 

 

Recommended

 

Use Only for Short Run Installations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4”

4”

 

2-1/2”

 

 

 

 

 

 

 

 

 

 

 

(10.2 cm)

(10.2 cm)

 

 

 

 

 

 

 

(6.35 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum length of 4” (10.2 cm) diameter rigid metal duct

 

 

 

 

 

 

 

 

0

 

 

65 feet (19.8 m)

 

 

55 feet (16.8 m)

 

 

 

 

 

 

 

 

1

 

 

55 feet (16.8 m)

 

 

47 feet (14.3 m)

 

 

 

 

 

 

 

 

2

 

 

47 feet (14.3 m)

 

 

41 feet (12.5 m)

 

 

 

 

 

 

 

 

3

 

 

36 feet (11.0 m)

 

 

30 feet (9.1 m)

4

 

 

28 feet (8.5 m)

 

 

22 feet (6.7 m)

 

Maximum length of 4” (10.2 cm) diameter flexible metal duct

 

 

 

 

 

 

 

 

0

 

 

45 feet (13.7 m)

 

 

35 feet (10.7 m)

 

 

 

 

 

 

 

 

1

 

 

35 feet (10.7 m)

 

 

27 feet (8.2 m)

 

 

 

 

 

 

 

 

2

 

 

30 feet (9.1 m)

 

 

21 feet (6.4 m)

 

 

 

 

 

 

 

 

3

 

 

25 feet (7.6 m)

 

 

17 feet (5.2 m)

4

 

 

20 feet (6.1 m)

 

 

15 feet (4.5m)

NOTE : Deduct 6 feet (1.8 m) for each additional elbow.

[ Table. 1]

2 0

Page 20
Image 20
LG Electronics D5932W, D2532W, D5911W, D2511W, DLE2511W manual Maximum length of 4 10.2 cm diameter rigid metal duct