• The recommended mounting height for the iCAM4100 is 140cm (55 inches) from the floor to the bottom of the
unit. This mounting height can be adjusted to accommodate the average user height at the installed location.
• High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may
reduce the image capture performance of the iCAM, this may result in an increased “failure to acquire” rate.
• The iCAM is not weatherproof and must not be exposed to precipitation or extreme temperatures. An enclosure
may be used to protect the unit if required. See www.lgiris.com – Support & Service for more information.
• All system components including the Ethernet network must be powered through Uninterruptible Power Supplies
(UPS). UPS must provide power line filtering as well as power back-up operation.
• Each IrisAccess™ system component on the Ethernet network system must have a unique manually assigned IP
address.
The iCAM4100 requires at least the following wires:
• Ethernet network wiring to connect with the network switch to communicate to the IrisServer or an ICU.
* Note: For systems consisting of only an IrisServer and iCAM may use an Ethernet crossover cable to connect
the iCAM directly to the IrisServer computer.
• Power (12VDC +/-10% and 2.5Amps MAX)
IMPORTANT: IT IS RECOMMENDED TO USE THE POWER ADAPTER SUPPLIED WITH THIS PRODUCT. AN OVER OR
UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.
3Installation Requirements
bottom of
mirror
floor
61”
(155mm)
55”
(140mm)