STEP 3: Prepare The Venting Blower

WALL-VENTED INSTALLATION:

1.Remove one blower unit mounting screw and one or

several blower plate mounting screw(s). Remove the blower plate from cabinet. See Figure 13.

2.Carefully lift the blower unit out of the microwave oven.

3.Use side cutters or tin snips to cut and remove knockouts

B from Back plate. Discard knockouts. Be careful not to distort the plate. See Figure 14.

4.Reassemble the blower wire. See Figure 15.

5.Rotate the blower unit so that the exhaust ports face the rear of the cabinet. See Figure 16.

6.Place blower unit back into cabinet. Check that the exhaust

ports face towards the rear of the cabinet. Be sure the wires are not pinched. See Figure 17.

7.Reattach the blower plate to cabinet so the exhaust ports and blower plate opening are aligned. Attach with one

blower unit mounting screw and then one or several blower plate mounting screw(s). See Figure 18.

Blower Plate

Mounting Screw

Blower Plate

Back Plate

Blower Unit

Blower Unit

Mounting Screw

Parts B

Figure 13

Knockouts Parts B

Parts B

Figure 14

Blower

Unit

Exhaust Ports

Figure 15

Figure 16

Blower Plate

Mounting Screw

Blower Plate

Blower Unit

Back Plate

Exhaust

 

Blower Unit

Ports

 

Blower Unit

Mounting Screw

 

 

Exhaust Ports

 

Figure 17

 

Figure 18

– 11

Page 11
Image 11