LG Electronics LSU120CE, LSN090CE, LSU090HE, LSU090CE Piping Length And Elevation, Evap Moz/ft

Models: LSN180HE LSN120HE LSN090CE, LSN120CE, LSN180CE, LSN240CE, LSN090HE, LSN120HE, LSN180HE, LSN240HE, LSU090CE, LSU120CE, LSU180CE, LSU240CE, LSU090HE, LSU120HE, LSU180HE, LSU240HE LSN240CE LSU240HE LSU090CE LSU240CE LSN120CE LSN180CE LSU120HE LSU180HE LSU180CE LSN090CE LSN240HE LSN090HE LSU090HE LSU120CE

1 83
Download 83 pages 59.19 Kb
Page 18
Image 18

PipingLengthAndElevation

Capacity

Pipe Size

Standard

Max.

Max.

Additional Refrigerant

 

 

Length

Elevation

length

(Btu/h)

Suction

Evap

g/m(oz/ft)

m(ft)

B m(ft)

A m(ft)

 

 

 

 

 

 

 

 

9k(C/O)

3/8"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

9k(H/P), 12k

1/2"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

 

 

 

 

 

 

 

18k(C/O)

1/2"

1/4"

7.5(25)

15(49)

30(98)

20(0.22)

 

 

 

 

 

 

 

18k(H/P), 24k

5/8"

1/4"

7.5(25)

15(49)

30(98)

30(0.32)

 

 

 

 

 

 

 

A

Indoor unit

Outdoor unit

B

Outdoor unit

Oil trap

A

 

Indoor unit

 

B

In case more than 5m(16.4ft)

Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Oil trap should be installed every 5~7meters (16.4~23.0ft).

18Room Air Conditioner

Page 18
Image 18
LG Electronics LSU120CE, LSN090CE, LSU090HE, LSU090CE, LSN180CE, LSN120HE, LSN180HE Piping Length And Elevation, Evap Moz/ft