LG Electronics LSN180CE, LSN090CE, LSU120CE Connecting The Piping, Indoor unit installation

Models: LSN180HE LSN120HE LSN090CE, LSN120CE, LSN180CE, LSN240CE, LSN090HE, LSN120HE, LSN180HE, LSN240HE, LSU090CE, LSU120CE, LSU180CE, LSU240CE, LSU090HE, LSU120HE, LSU180HE, LSU240HE LSN240CE LSU240HE LSU090CE LSU240CE LSN120CE LSN180CE LSU120HE LSU180HE LSU180CE LSN090CE LSN240HE LSN090HE LSU090HE LSU120CE

1 83
Download 83 pages 59.19 Kb
Page 21
Image 21

ConnectingThePiping

Indoor

1.Prepare the indoor unit's piping and drain hose for installation through the wall.

2.Remove the plastic tubing retainer(see the illus-

tration by) and pull the tubing and drain hose away from chassis.

3. Replace only the plastic tubing holder 1, not the holder 2 in the original position.

For left rear piping

Route the indoor tubing and the drain hose in the direction of rear left.

Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy con- nection later.

Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.

NOTICE

1

2

 

Connecting

 

cable

 

Drain pipe

If the drain hose is routed inside the room, insu- late the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recom- mended.

Indoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the three hooks of the rear top and rear lower of the indoor unit with the upper edge and lower edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Indoor unit

Installation plate 8cm

Spacer

Service Manual 21

Page 21
Image 21
LG Electronics LSN180CE, LSN090CE, LSU120CE, LSU090HE, LSU090CE, LSN120HE Connecting The Piping, Indoor unit installation