LG Electronics LSN240CE, LSN090CE Connection Of The Drain Hose, Connection Of Piping -Outdoor

Models: LSN180HE LSN120HE LSN090CE, LSN120CE, LSN180CE, LSN240CE, LSN090HE, LSN120HE, LSN180HE, LSN240HE, LSU090CE, LSU120CE, LSU180CE, LSU240CE, LSU090HE, LSU120HE, LSU180HE, LSU240HE LSN240CE LSU240HE LSU090CE LSU240CE LSN120CE LSN180CE LSU120HE LSU180HE LSU180CE LSN090CE LSN240HE LSN090HE LSU090HE LSU120CE

1 83
Download 83 pages 59.19 Kb
Page 26
Image 26

ConnectionOfTheDrainHose

The drain hose can be connected at two different positions. Use the most convenient position and, if necessary, exchange the position of the drain pan, rubber cap and the drain hose.

Drain pan

Rubber cap

Drain hose

Exchange if necessary

Remove the drain hose.

Securely insert both the rubber plug and drain hose into the drain outlets.

Be sure the rubber the cap is securely fastened so that there is no leakage.

2

4

3

1

ConnectionOfPiping-Outdoor

Put a couple drops of refrigerant oil on

the face of the flare before assembling

Outdoor unit

taking care not to add any contaminants.

Align the center of the pipings and suffi- ciently tighten the flare nut by hand.

Finally, tighten the flare nut with torque wrench until the wrench clicks.

When tightening the flare nut with torque wrench, ensure the direction for tightening fol- lows the arrow on the wrench.

Suction Line piping (Bigger diameter)

Evaporator Line piping (Smaller diameter)

Torque wrench

 

Outside diameter

 

Torque

 

mm

inch

 

 

 

Ø6.35

1/4

 

1.8

 

 

Ø9.52

3/8

 

4.2

 

 

Ø12.7

1/2

 

5.5

 

 

Ø15.88

5/8

 

6.6

 

 

Ø19.05

3/4

 

6.6

 

26Room Air Conditioner

Page 26
Image 26
LG Electronics LSN240CE, LSN090CE, LSU120CE, LSU090HE, LSU090CE Connection Of The Drain Hose, Connection Of Piping -Outdoor