APPENDIX

16. Auto Configure (Command: j u)

G To adjust picture position and minimize image shaking automatically. It works only in RGB (PC) mode.

Transmission

[j][u][ ][Set ID][ ][Data][Cr]

Data 01: To set

Ack

[u][ ][Set ID][ ][OK/NG][Data][x]

17. Equalize (Command: j v)

G To adjust equalize.

Transmission

[j][v][ ][Set ID][

][Data][Cr]

 

 

 

 

 

 

MSB

 

 

 

 

 

 

 

 

 

 

 

 

LSB

Data :

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

0

 

0

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

 

 

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency :

0

 

 

 

 

 

 

120 Hz

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

200 Hz

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

500 Hz

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

1.2 kHz

 

 

 

 

 

* Real data mapping 1

00 : Step 0

A : Step 10 (Set ID 10)

F: Step 15 (Set ID 15)

10 : Step 16 (Set ID 16)

64:Step 100 6E : Step 110

73 : Step 115

74 : Step 116

C7: Step 199

FE : Step 254

FF : Step 255

*Real data mapping 2

00 :-40

01 : -39

02 :-38

28 :0

4E : +38

4F : +39

50 : +40

4

3 kHz

5

7.5 kHz

612 kHz

Step (Frequency data):

Refer to ‘Real data mapping 3 ’.See page 97.

Ack

[v][ ][Set ID][ ][OK/NG][Data][x]

* Equalize command expression

7

6

5

4

3

2

1

0

Frequency

0

0

0

 

 

 

 

 

120Hz

 

 

 

 

 

 

 

 

 

0

0

1

 

 

 

 

 

200Hz

 

 

 

 

 

 

 

 

 

0

1

0

 

 

 

 

 

500Hz

 

 

 

 

 

 

 

 

 

0

1

1

 

 

 

 

 

1.2KHz

 

 

 

 

 

 

 

 

 

1

0

0

 

 

 

 

 

3KHz

 

 

 

 

 

 

 

 

 

1

0

1

 

 

 

 

 

7.5KHz

 

 

 

 

 

 

 

 

 

1

1

0

 

 

 

 

 

12KHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step

 

 

OSD

7

6

5

4

3

2

1

0

Value

 

 

 

 

0

0

0

0

0

-24

 

 

 

 

 

 

 

 

 

 

 

 

..

..

..

..

..

..

 

 

 

 

 

 

 

 

 

 

 

 

0

1

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

..

..

..

..

..

..

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

1

24

 

 

 

 

 

 

 

 

 

Ex) If you wish to set frequency 500Hz and -20 value on menu OSD,refer to ‘Real data mapping 3’ and then find Step value for -20.

010 (500Hz)00011(Step 3)=>01000011 =>43 (Hexadecimal):[j ][v ][ ][Set ID ][ ][43 ][Cr ]

*3 bits of Frequency and 5 bits of Step makes 8 bits (1 byte). Change 8 bits to Hexadecimal code.

96

Page 97
Image 97
LG Electronics M2794D, M2394D owner manual Lsb