TROUBLESHOOTING
Your appliance is designed and manufactured for a long life span and reliable operation.
If a malfunction nonetheless occurs during operation, check whether it is due to an operating error. Please note that even during the warranty period the resultant servicing costs in this case will have to be borne by the owner.
You may be able to rectify the following faults by checking the possible causes yourself:
Malfunction Possible cause and remedy
__________________________________________________
Appliance does not work, display is off
-Is the appliance switched on properly?
-Is the power cord properly inserted in the outlet?
-Is the circuit breaker or fuse in operating condition?
The interior light does not come on
-Is the appliance switched on?
-Has the door been open for more than 15 minutes?
-The bulb/lighting unit* is defective. Change the bulb/lighting unit* as described in "Interior light".
Loud running noise
-Is the appliance standing firmly on the floor, or does the compressor cause nearby items of furniture or objects to vibrate? If necessary, move the appliance slightly, align by adjusting the adjustable feet, or move bottles and containers apart.
-Burbling noises are normal. These are caused by the refrigerant flowing round the refrigerant circuit. A short clicking sound: This will be heard whenever the refrigeration unit (the motor) switches on or off automatically.
Motor noise: This will be slightly louder for a brief period when the refrigeration unit switches on.
The audible warning signal sounds
- Is the appliance closed properly? Check the appliance as described in "Audible warning signal".
The temperature is not cold enough
-Is the temperature setting correct? If necessary, set a lower temperature and check the display after 24 hours.
-Does the door close properly?
-Is the appliance sufficiently well ventilated? Clear ventilation grilles if necessary.
-Is the ambient temperature too hot? (See "Safety regulations")
-Has the appliance been opened too often or left open too long?
-If applicable, wait until the appliance reaches the required temperature itself.
* Depending on model and options
RBI/RB 1400 EKB/es 4250 | 13 |