7SERVICE & PRODUCT MAINTENANCE

7.1TROUBLESHOOTING

Problem

Cause / Solution

 

Check to see that the power cord is fully plugged into the back of the

 

Total-Body Elliptical Cross-Trainer and into the wall. Make sure the power

 

cord is fully seated into the back of the Total-Body Elliptical Cross-Trainer.

 

 

No power.

You may be in “Energy Saver Mode”. Press the “Energy Saver” button to

see if the console turns on.

 

 

 

 

Verify that all customer assembly connections are working properly.

 

Unplug and re-plug each connection to verify. Look to see if any cables

 

were pinched during assembly.

 

 

 

Remove the moving arm pivot covers and check to make certain the bolt

 

holding the total body arm in place is fully tightened. If the total body arms

Total Body Arms feel loose.

still feel loose, you may want to disassemble the total body arms and

 

make sure all of the proper hardware from the assembly instructions was

 

used.

 

 

 

Some noise from the pedals is normal. It will vary depending on the

Noise is coming from pedals.

weight of the user. Check assembly hardware beneath pedal to make

 

certain it is tight.

 

 

Hear noise as speed increases.

It is normal for any mechanical device to become louder as speed

increases.

 

 

 

 

Your product may be in ‘Safety Mode’. Refer to the console manual on

Start-Up resistance seems very diffi-

how to turn off this setting.

 

cult.

 

 

Turn the unit off and then on again.

 

 

Can’t feel a resistance change at the

The resistance curve of the Total-Body Elliptical Cross-Trainer is designed

beginning levels.

so that you can feel a greater difference in resistance at higher levels.

 

 

 

Potential reasons for the wireless heart rate not to work properly include:

 

1. The wireless heart rate is turned OFF in the Settings Menu. Enter

 

the Settings Menu and verify that WIRELESS HR is turned ON.

 

2. There is poor contact between the telemetry heart rate strap and

 

the skin.

Wireless heart rate is not working.

3. There is electrical interference from electrical appliances with the

 

telemetry heart rate strap from fluorescent lights, kitchen appliances,

 

etc. Move the Total-Body Elliptical Cross-Trainer to a different

 

location or move electrical appliances away from the Total-Body

 

Elliptical Cross-Trainer.

 

4. The battery in the Heart Rate Telemetry Strap needs to be replaced.

 

The battery is a CR2032 (3V).

 

 