![](/images/new-backgrounds/1291799/29179951x1.webp)
26
OPTIONAL SETTINGS FOR THE LIFECYCLE 9500HR AEROBIC TRAINER
l Maximum program time
The maximum program time option allows the maximum program time to be changed from the default maximum time limit of 60 minutes to anywhere from 1 to 99 minutes. Altering the maximum program time will affect all programs except the Fit Test. To change the Lifecycle 9500HR aerobic trainer maximum program time, proceed as follows:
1.Press and hold the 5 key on the numeric keypad.
2.Begin pedaling (you must reach a minimum of 55 RPM), then press START.
All LEDs and
3.When you reach Diagnostic State 5, the current MAXIMUM PROGRAM TIME setting will be displayed. The default maximum program time is 60 minutes.
4.Use the 1 key or t key to decrease the MAXIMUM PROGRAM TIME or the 3 key or s key to increase the MAXIMUM PROGRAM TIME.
5.To exit the Diagnostic States, press the CLEAR/PAUSE key repeatedly until you return to the user display. The user display is the initial display console you see when you approach the unit for normal operation.
l Telemetry enable/disable
The factory default is set to telemetry enabled. When you reach Diagnostic State 6 (see above), the Data Entry Window will display ON. To disable the telemetry func- tion, press the 5 key and the system will toggle between On and Off.
l English/metric conversion
The factory default is set to english measurement. When you reach Diagnostic State 7 (see above), the Data Entry Window will display E to designate english units. To change the default to metric measurement, press an arrow key and the system will toggle between english and metric units.