Life Fitness 95C owner manual Malfunction, Probable Cause, Corrective Action

Models: 95C

1 15
Download 15 pages 15.59 Kb
Page 11
Image 11

2.3Troubleshooting the Optional Polar® Telemetry Heart Rate Chest Strap

Heart Rate Reading Is Initially Detected then Lost or Abnormally Elevated

Malfunction

Probable Cause

Corrective Action

 

 

 

 

Use of personal electronic

 

 

devces, such as cell phones

 

 

and portable MP3 players, caus-

 

 

es external noise interference.

 

Heart rate reading is initially

 

Remove the source of noise or

detected and functioning nor-

 

reposition the exercise

mally but then is lost.

Equipement is in close proximity

equipment.

 

to other sources of noise such

 

 

as audio/ video equipment,

 

 

fans, two way radios, and high

 

 

voltage/highcurrent power lines.

 

 

 

 

 

Television sets and/or

 

 

antennas generate electromag-

 

 

netic interference.

 

 

 

 

 

Cell phones generate electro-

 

 

magnetic interference.

 

 

 

 

 

Computers generate electro-

 

 

magnetic interference.

 

 

 

Move the treadmill a few inches

 

 

away from the probable cause,

 

 

Heart rate readings are

Cars generate electromagnetic

or move the probable cause a

abnormally elevated.

interference.

few inches away from the tread-

 

 

mill, until the heart rate readings

 

 

are accurate.

 

High voltage power lines gener-

 

ate electromagnetic interfer-

 

 

ence.

 

 

 

 

 

Motor driven exercise equip-

 

 

ment generates electromagnetic

 

 

interference.

 

 

 

 

 

Another heart rate transmitter

 

 

within three feet (one meter)

 

 

generates electromagnetic inter-

 

 

ference.

 

 

 

 

10

Page 11
Image 11
Life Fitness 95C owner manual Malfunction, Probable Cause, Corrective Action