Model 200ERV

®

CLEAN • FRESH • AIR

ENGINEERING DATA

LATENT RECOVERY/MOISTURE TRANSFER CORE

The cross-flow energy recovery core transfers heat and water vapour between the two airstreams. It is easily removed for cleaning or service.

MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. High speed - 120 VAC, 182 Watts.

FILTERS - Washable air filters in exhaust and supply air streams.

MOUNTING THE ERV - Four threaded inserts at corners of case designed to accept four PVC reinforced polyester straps that are supplied with the unit.

CASE - Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation.

CONTROLS - ControlAir 15

WEIGHT 63 lbs. (28.7 kg) SHIPPING WEIGHT 65 lbs. (29.6 kg)

Model 200ERV

PERFORMANCE

Net supply airflow in cfm (L/s) against external static pressure

E.S.P

cfm

L/s

@ 0.1” (25 Pa)

214

(101)

@ 0.2” (50 Pa)

206

(97)

@ 0.3” (75 Pa)

193

(91)

@ 0.4” (100 Pa)

184

(87)

@ 0.5” (125 Pa)

170

(80)

Sensible Effectiveness

67%

@127cfm (60 L/s) (CSA C439M)

 

Sensible Efficiency 32°F (0°C)

60%

Total Efficiency

55%

 

 

VAC @ 60HZ

120

 

 

WATTS / Low speed

70

DIMENSIONS 200ERV inches (mm)

*All Duct Connections 6"(150mm)

ENTHALPIC CORE

STALE AIR

MOTOR

FRESH AIR

FROM INSIDE

 

 

TO INSIDE

 

 

FILTERS

 

BALANCING

 

 

DAMPER

FRESH AIR

 

STALE AIR

 

TO OUTSIDE

FROM OUTSIDE

 

 

 

 

31"

BLOWERS

 

(787)

 

OPTIONS

 

WARRANTY

19"

(483)

*NOTE: Front clearance of 25 inches (635 mm) is recommended

for servicing unit.

14 3/4"

(375)

99-104 Digital Electronic Timer - 20/40/60 min. (3 wire) 99-105 Deluxe Programmable Control includes

Programmable Time Clock, Dehumidistat

and Air Sentry™

99-109 Air Sentry™ Air Quality Monitor designed to accept remotely mounted Control Pad

Units carry a 5 year warranty on the energy recovery core and replacement parts.

All units conform to CSA and UL standards.

ERVs are not recommended for regions where the design temperature is below 25°F (-4°C)

99-186 Weatherhoods, Two - 6” (150mm)

c/w 1/4” (6mm) mesh screen

DATE: __________________________

 

511 McCormick Blvd.

PROJECT: __________________________________________

London, Ontario N5W 4C8

Ph: (519) 457-1904

 

Fx: (519) 457-1676

MECHANICAL CONTRACTOR: _____________________________

Email: nutech@lifebreath.com

Website: www.lifebreath.com

11

TI-98E

0202

 

Page 11
Image 11
Lifebreath MAXTOP, 200MAX, 95MAX, 155MAX Model 200ERV, DIMENSIONS 200ERV inches mm, Engineering Data, Performance, Options