Lifebreath 300DCS Installation Diagrams, Partially Dedicated System, Forced Air Furnace, Outdoors

Models: MAXTOP 195DCS 200ERVD 200ERV 300DCS 155MAX 95MAX 200MAX

1 32
Download 32 pages 16.73 Kb
Page 21
Image 21
Installation Diagrams

Installation Diagrams

Example diagram only - duct configuration may change depending on model

Partially Dedicated System

DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN

(Stale air drawn from key areas of home)

EXHAUST AIR from various parts of home.

i.e. bathrooms (if required), kitchens (if required).

Partially Dedicated System Return Air

Outdoors

3’ min.

 

recommended

Cool Air

Return

*Unit is normally balanced on HIGH speed with furnace blower ON.

NOTES:

1.Furnace blower may be required to operate when HRV/ERV is on to provide good air distribution.

2.Weatherhood arrangement is for drawing purposes only. 6' (2 m) minimum separation required. 18" (460 mm) above grade minimum.

3.Due to the differences in pressure between the HRV/ERV and the equipment it is being connected to, the HRV/ERV's airflow must be confirmed on site, using the balancing procedure found in the installation manual.

Forced Air

Furnace

21

Page 21
Image 21
Lifebreath 300DCS Installation Diagrams, Partially Dedicated System, Stale air drawn from key areas of home, Outdoors