Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 



 

 

DEG.

0

22.5

45

67.5

90

 

 

 

 

 

 

 

 

 

 



 

180

2893

2893

2893

2893

2893

 

 

 

 



 

175

2878

2881

2893

2899

2902

 

 

 

 



165

2776

2795

2847

2873

2886

 

 

 

 



155

2584

2627

2731

2800

2829

 

 

 

 

 

 

145

2307

2381

2555

2642

2676

 

 

 

 



135

1953

2074

2285

2353

2384

 

 

 

 

 



125

1536

1703

1907

1922

1965

 

 

 

 

 



 

 

 



115

1074

1284

1417

1356

1386

 

 

 

105

591

741

792

717

756

 

 

 

 

 

 



 

 

 



95

138

141

200

149

185

 

 

 

 

 

90

3

3

10

3

7

 

 

 

 



 

 

 

 

 

 

85

0

0

0

0

0



 

 

 



 

 

 

 

 

 

75

0

0

0

0

0

 

 

 

 



 



 



 



 

65

0

0

0

0

0

 

 





 

 

55

0

0

0

0

0

Report No: 2101583

45

0

0

0

0

0

35

0

0

0

0

0

Lamps: F32T8

 

 

 

 

25

0

0

0

0

0

Lumens per Lamp: 2950

15

0

0

0

0

0

Efficiency: 80.7%

5

0

0

0

0

0

Up: 100.0% Down: 0.0%

0

0

0

0

0

0

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

4 Light T8 Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

76

76

76

65

65

65

 

44

44

44

1

66

63

61

57

54

52

 

39

37

36

2

58

53

49

49

46

43

 

34

31

30

3

51

45

41

43

39

35

 

30

27

25

4

44

39

34

38

33

30

 

26

23

21

5

39

33

29

34

29

25

 

23

20

18

6

35

29

25

30

25

21

 

20

17

15

7

31

25

21

27

22

18

 

18

15

13

8

28

22

18

24

19

16

 

16

13

11

9

25

20

16

22

17

14

 

15

12

10

10

23

18

14

20

15

12

 

13

11

8

Zonal Lumen Summary

 

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

0

0

0

90-180

9517

80.7

100.0

0-180

9517

80.7

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL24, Module Lengths & Mounting Distances, Run Configuration, Type, Performance