Troubleshooting Checklist
Table 5-1 LANVIEW LEDs (continued)
LED | Color | State | Recommended Action |
|
|
|
|
TX | None | Port enabled, but no activity. | If it is known that the port should be active |
(Transmit) |
|
| and is not, contact Enterasys Networks for |
|
|
| technical support. |
|
|
|
|
| Green | Flashing. Indicates data | None. |
|
| transmission activity. Rate of |
|
|
| flashing indicates the data rate. |
|
|
|
|
|
| Red | Flashing. Fault or Error | None, unless there is a high rate of activity. |
|
| (collision). | In this case, check for network configuration |
|
|
| problems or a defective device. |
|
|
|
|
Troubleshooting Checklist
If the NAC Controller PEP is not working properly, refer to Table 5‐2 for a checklist of problems, possible causes, and recommended actions to resolve the problem.
Table
Problem | Possible Cause | Recommended Action |
|
|
|
All LEDs are OFF. | Loss of power. | Ensure that the module was installed properly |
|
| according to the installation instructions in Chapter 4, |
|
| and that the host chassis is providing power. |
|
|
|
No Local | Incorrect terminal setup. | Refer to the Enterasys Matrix |
Management |
| Series Configuration Guide for proper setup |
Password screen. |
| procedures. |
|
|
|
| Improper console cable | Refer to |
| pinouts. | on page |
|
| Assignments” on page |
|
| PEP COM port pinouts. |
|
|
|
| Corrupt firmware image, or | If possible, attempt to download the image to the |
| hardware fault. | module again. Refer to “Setting the Mode Switches” on |
|
| page |
|
|
|
Cannot navigate | Improper username/ | If the username/password combination has been |
beyond Password | password combination | forgotten, refer to “Setting the Mode Switches” on |
screen. | entered. | page |
|
| switch to reset the username/password combination to |
|
| the default values. |