2S4082-25 COM Port Pinout Assignments

2S4082-25 COM Port Pinout Assignments

The COM port is a serial communications port for local access to Local Management. Refer to Table A‐6 for the COM port pin assignments.

Table A-8 COM Port Pin Assignments

Pin

Signal Name

Input/Output

 

 

 

1

Transmit Data (XMT)

Output

 

 

 

2

Clear to Send (CTS)

Input

 

 

 

3

Data Set Ready (DSR)

Input

 

 

 

4

Receive Data (RCV)

Input

 

 

 

5

Signal Ground (GND)

NA

 

 

 

6

Request to Send (RTS)

Output

 

 

 

7

Data Terminal Ready (DTR)

Output

 

 

 

8

Data Carrier Detect (DCD)

Input

 

 

 

NAC Controller PEP 7S4280-19 Specifications

Table A‐9 provides the I/O ports, processors and memory, physical, and environmental module specifications for the 7S4080‐19 NAC Controller PEP.

Table A-9 Specifications

Item

Specification

 

 

7S4280-19 Ports

 

 

 

Ports 1 through 18

Mini-GBIC slots for up to 18 mix-and-match 1000BASE-SX, -LX,

 

-ELX and 1000BASE-T compliant Mini-GBICs. Refer to

 

Mini-GBIC Input/Output Specifications” on page A-7.

NEM Slot

The NAC Controller Engine is pre-installed.

 

 

Processors/Memory

 

 

 

Processor

IBM 750CXe, 600 MHz processor

Dynamic Random Access Memory

256 MB

(DRAM)

 

FLASH Memory

32 MB

 

 

Physical

 

Dimensions

Approximate Weight

Predicted hours for Mean Time Between Failures (MTBF) for NAC Controller PEPs:

46.43H x 6.05 W x 29.51 D (cm)

18.28H x 2.38 W x 11.62 D (in.)

Gross: 5.0 kg (11.0 lb.) (shipping carton containing one module)

Net: 3.86 kg (8.5 lb.) (one module without packaging)

Refer to the MTBF web site at this URL:

http://www.enterasys.com/support/mtbf/

A-6 Specifications and Regulatory Compliance

Page 96
Image 96