Troubleshooting Checklist

 

Table 5-2 Troubleshooting Checklist (continued)

 

 

 

 

 

Problem

Possible Cause

Recommended Action

 

 

 

 

 

Cannot contact the

IP address not assigned.

Refer to the Enterasys Matrix DFE-Diamond/Platinum

 

module through

 

Series Configuration Guide for the IP address

 

in-band

 

assignment procedure.

 

management.

 

 

 

Port is disabled.

Enable port. Refer to the Enterasys Matrix

 

 

DFE-Diamond/Platinum Series Configuration Guide for instructions to enable/disable ports.

Host Port policy and/or management VLAN is incorrectly configured, or not configured.

Verify that a management VLAN exists and that it is associated with the Host Port.

Refer to the Enterasys Matrix DFE-Diamond/Platinum Series Configuration Guide for information about Host Port and management VLAN configuration.

 

No link to device.

Verify that all network connections between the

 

 

network management station and the module are valid

 

 

and operating.

 

 

If the problem continues, contact Enterasys Networks

 

 

for technical support.

 

 

 

Port(s) goes into

Loop condition detected.

Verify that Spanning Tree is enabled. Refer to the

standby for no

 

Enterasys Matrix DFE-Diamond/Platinum Series

apparent reason.

 

Configuration Guide for the instructions to set the type

 

 

of STA.

 

 

Review the network design and delete unnecessary

 

 

loops.

 

 

If the problem continues, contact Enterasys Networks

 

 

for technical support.

 

 

 

User parameters

Position of Mode switch (7),

Reenter the lost parameters as necessary. Refer to the

(IP address, device

Persistent Data Reset, was

Enterasys Matrix DFE-Diamond/Platinum Series

and module name,

changed sometime before

Configuration Guide for the instructions to configure

etc.) were lost

either cycling power or

the device.

when the module

pressing the

If the problem continues, contact Enterasys Networks

power was cycled,

OFFLINE/RESET switch,

for technical support.

the front panel

causing the user-entered

 

OFFLINE/RESET

parameters to reset to

 

switch was

factory default settings.

 

pressed.

Clear Persistent Data that

 

 

 

 

was set through Local

 

 

Management.

 

 

The module was moved

 

 

either from slot-to-slot or

 

 

from chassis-to-chassis.

 

 

 

 

Enterasys NAC Controller Hardware Installation Guide 5-5

Page 65
Image 65
Enterasys Networks 2S4082-25-SYS, 7S4280-19-SYS manual Troubleshooting Checklist, Problem Possible Cause Recommended Action