7C111 Chassis Specifications and Regulatory Compliance

Table A-5 NAC Controller Engine Specifications (continued)

Item

Specification

 

 

DC Output Voltage

12v

DC Output Amps

5A

Physical

 

Dimensions

• Width: 10.65 in. (27.05 cm)

 

• Length: 7.3 in. (18.54 cm)

 

• Depth: 1.8 in (4.57 cm)

Predicted hours for Mean Time

For the MTBF hours for this module, refer to the MTBF web

Between Failures (MTBF)

site at URL

 

http://www.enterasys.com/support/mtbf/

Maximum Wattage

50 Watts

 

 

Environmental

 

 

 

Operating Temperature

0°C to 40°C (32°F to 104°F)

Storage Temperature

-30°C to 73°C (-22°F to 164°F)

Operating Relative Humidity

5% to 90% (non-condensing)

Minimum Air Flow

200 Linear Feet / Minute

 

 

NAC Controller Engine COM Port Pinout Assignments

The COM port is a serial communications port for local access to Local Management. Refer to Table A‐6 for the COM port pin assignments.

Table A-6 COM Port Pin Assignments

Pin

Signal Name

Input/Output

 

 

 

1

Transmit Data (XMT)

Output

 

 

 

2

Clear to Send (CTS)

Input

 

 

 

3

Data Set Ready (DSR)

Input

 

 

 

4

Receive Data (RCV)

Input

 

 

 

5

Signal Ground (GND)

NA

 

 

 

6

Request to Send (RTS)

Output

 

 

 

7

Data Terminal Ready (DTR)

Output

 

 

 

8

Data Carrier Detect (DCD)

Input

 

 

 

A-4 Specifications and Regulatory Compliance

Page 94
Image 94
Enterasys Networks 7S4280-19-SYS, 2S4082-25-SYS NAC Controller Engine COM Port Pinout Assignments, Environmental, Physical