7C111 Chassis Specifications and Regulatory Compliance

Power Supply

Table A-2 7C111 Power Supply Specifications

Item

Specification

 

 

Electrical

 

 

 

Accepts up to (2) IEC320 C13 power cord plugs

 

 

 

Input Frequency:

50 to 60 Hz

 

 

Input (Voltage/Amps):

2 x 100 to 125 Vac ~ 3.6 A

 

2 x 200 to 240 Vac ~ 1.6 A

 

 

Input Power:

400 W

 

 

Output Voltages:

5 V @ 40 amps

 

12 V @ 5.5 amps

 

3.3 V @ 40 amps

 

-12 V @ 2 amps

 

 

Environmental Requirements

The environmental specifications for the N1 chassis system are as follows:

Table A-3 Environmental Specifications

Item

Specification

 

 

Operating Temperature:

5°C to 40°C (41°F to 104°F)

 

 

Storage Temperature:

-30°C to 73°C (-22°F to 164°F)

 

 

Operating Relative Humidity:

5% to 90% (non-condensing)

 

 

Regulatory Requirements

Table A‐4 provides the safety and electromagnetic compatibility (EMC) requirements met by the

N1 chassis system:

Table A-4 Regulatory Compliance Standards

Item

Specification

 

 

Safety:

Safety: UL 60950, CSA C22.2 No. 60950, 2006/95/EC,

 

EN 60950, IEC 60950.

 

Modules which support laser connections also meet the

 

EN 60825 and 21 CFR 1040.10 standards.

 

 

Electromagnetic Compatibility (EMC) FCC:

47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN

 

55022, EN 61000-3-2, EN 61000-3-3, EN 55024,

 

AS/NZS CISPR 22, VCCI V-3.

 

 

A-2 Specifications and Regulatory Compliance

Page 92
Image 92
Enterasys Networks 7S4280-19-SYS, 2S4082-25-SYS manual Environmental Requirements, Regulatory Requirements, Power Supply