Lightolier Lighting Systems Baselyte-BSL7, Page of, Performance, Run Configuration, Type

Models: Baselyte-BSL7

1 8
Download 8 pages 8.96 Kb
Page 2
Image 2
Lighting Systems  Baselyte-BSL7

Lighting SystemsBaselyte-BSL7

Page of 8

Performance

Candlepower Curve

 







 

 

 

 

 

 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 



 

 

 





 

 





 

 



 

 

 

 

 

 





 

 



 

 

 

 

 

 





 

 



 

 

 

 







 

 

Report No: 2101637

Lamps: F54T5

Lumens per Lamp: 4650

Efficiency: 88.5%

Up: 87.0% Down: 13.0%

Candlepower Summary

ZONE

 

CANDLEPOWER

 

DEG.

0

22.5

45

67.5

90

180

3780

3780

3780

3780

3780

175

3757

3762

3776

3787

3790

165

3617

3654

3726

3782

3804

155

3361

3443

3610

3745

3800

145

2994

3135

3442

3704

3795

135

2527

2752

3231

3577

3701

125

1981

2325

2930

3286

3418

115

1384

1867

2442

2658

2768

105

742

1261

1585

1586

1679

95

166

337

474

409

489

90

11

47

67

76

77

85

34

51

74

82

86

75

84

94

110

120

125

65

151

207

181

172

177

55

313

347

319

261

265

45

513

446

495

456

453

35

712

621

610

638

643

25

896

849

715

689

710

15

1044

1064

978

895

891

5

1135

1136

1152

1160

1162

0

1144

1144

1144

1144

1144

4 Light T5 HO Direct/Indirect

Coefficients of Utilization

 

 

 

 

 

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

 

50

30

10

 

50

30

10

0

 

87

87

87

 

76

76

76

 

55

55

55

1

 

75

72

69

 

66

63

61

 

48

46

45

2

 

66

61

56

 

58

53

50

 

42

39

37

3

 

58

52

47

 

51

46

42

 

37

34

31

4

 

51

44

39

 

45

39

35

 

33

29

26

5

 

45

38

34

 

40

34

30

 

29

26

23

6

 

40

34

29

 

35

30

26

 

26

22

20

7

 

36

30

25

 

32

26

22

 

24

20

17

8

 

33

26

22

 

29

23

20

 

21

18

15

9

 

30

23

19

 

26

21

17

 

19

16

13

10

 

27

21

17

 

24

19

15

 

18

14

12

Zonal Lumen Summary

 

 

 

 

 

 

ZONE

LUMENS

 

%BARE LAMP

%LUMINAIRE

 

0-90

 

2134

 

11.5

 

 

13.0

 

 

90-180

14324

 

77.0

 

 

87.0

 

 

0-180

16458

 

88.5

 

 

100.0

 

 

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL7, Page of, Performance, Module Lengths & Mounting Distances, Run Configuration