TROUBLESHOOTING GUIDE
IMPINGER II ADVANTAGE
SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)
MODEL | NAT. GAS | 230VAC | 50 HZ. | 1 PHASE | |
MODEL | LP GAS | 230VAC | 50 HZ. | 1 PHASE | |
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS |
| ||||
|
|
|
|
| |
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
|
| |
Oven fan will not run | Incoming power supply | Check breaker, reset if required. Check power plug to | |||
|
|
| be sure it is firmly in receptacle. Measure incoming | ||
|
|
| power, call power co. if needed. |
| |
| Fuse, 10 amp |
| Check, replace if necessary. |
| |
| Fuse holder |
| Check, replace if necessary. |
| |
| Check for voltage on both sides of switch. Terminals are | ||||
|
|
| normally closed. If open, reset and test oven for proper | ||
|
|
| operation. If thermostat will not hold, and control box | ||
|
|
| temperature is not exceeding 140°F (60°C), replace | ||
|
|
| thermostat. |
|
|
| Switch, main fan |
| With power off, check continuity between switch | ||
|
|
| terminals. Replace as needed. |
| |
| Motor, main fan |
| Check for opens, shorts or grounds. With power off, turn | ||
|
|
| fan blade to check for locked rotor. | ||
| Capacitor |
| Check for shorts or grounds. |
| |
|
|
| WARNING: Capacitor has a stored charge, discharge | ||
|
|
| before testing. |
|
|
No control box cooling | Incoming power supply | Check breaker, reset if required. Check power plug to | |||
|
|
| be sure it is firmly in receptacle. Measure incoming | ||
|
|
| power, call power co. if needed. |
| |
| Switch, main fan |
| With power off, check continuity between switch | ||
|
|
| terminals. Replace as needed. |
| |
| Cooling fan |
| Line voltage should now be at the cooling fan. If voltage | ||
|
|
| is present, check motor for opens, shorts or grounds. | ||
|
|
| With power off, check for locked rotor. | ||
No automatic control | Incoming power supply | Check breaker, reset if required. Check power plug to | |||
box cooling |
|
| be sure it is firmly in receptacle. Measure incoming | ||
|
|
| power, call power co. if needed. |
| |
| Cooling fan thermostat | Check the cooling fan thermostat (thermostat closes at | |||
|
|
| 120°F and opens at 100°F). With the cooling fan | ||
|
|
| thermostat | ||
|
|
| thermostat is open, replace cooling fan thermostat. | ||
| Cooling fan |
| Line voltage should now be at the cooling fan. If voltage | ||
|
|
| is present, check motor for opens, shorts or grounds. | ||
|
|
| With power off, check for locked rotor. | ||
Oven will not heat | Gas supply |
| Check for adequate gas supply and be sure that the | ||
Serial Number |
|
| manual gas shut off valve is open. Also check flexible | ||
2045407 & Below |
|
| gas line connection. |
| |
| Main fan |
| If not operating, refer to “Oven fan will not run”. | ||
| Gas pressure switch | This switch is located inside the gas valve and should | |||
|
|
| close when gas pressure is present. | ||
|
|
| WITH POWER OFF: Remove 3 prong plug (on gas | ||
|
|
| valve) and measure continuity between terminals 2 and | ||
|
|
| 3. If no continuity, check the following: Proper gas | ||
|
|
| pressure supply to gas valve as marked on the oven | ||
|
|
| specification plate. Check for proper adjustment of the | ||
|
|
| gas pressure switch, 10 for Nat. gas, 27 for LP gas or | ||
|
|
| 4.5 for town gas. Check the filter in gas valve for |
8 | Impinger II – Advantage Digital Service Manual - International |