| terminals. Replace as needed. |
|
|
| Cooling fan | Line voltage should now be at the cooling fan. If voltage |
|
|
|
| is present, check motor for opens, shorts or grounds. |
|
|
|
| With power off, check for locked rotor. |
|
| No automatic control | Incoming power supply | Check breaker, reset if required. Check power plug to |
|
| box cooling |
| be sure it is firmly in receptacle. Measure incoming |
|
|
|
| power, call power co. if needed. |
|
|
| Oven cavity | Terminals are normally closed, opens at 660°F (350°C). |
|
|
| thermostat | If open, reset and test oven for proper operation. If |
|
|
|
| thermostat will not hold for maximum oven temperature, |
|
|
|
| and oven is not exceeding control setting, check for |
|
|
|
| proper location of capillary bulb ion its spring holder. If |
|
|
|
| above checks are okay, replace |
|
|
| Fuse, 10 amp | Check, replace if necessary. |
|
|
| Fuse holder | Check, replace if necessary. |
|
|
| Check for voltage on both sides of switch. Terminals are |
| |
|
| box | normally closed. If open, reset and test oven for proper |
|
|
|
| operation. If thermostat will not hold, and control box |
|
|
|
| temperature is not exceeding 140°F (60°C), replace |
|
|
|
| thermostat. |
|
|
| Cooling fan thermostat | Check the cooling fan thermostat (thermostat closes at |
|
|
|
| 120°F and opens at 100°F). With the cooling fan |
|
|
|
| thermostat |
|
|
|
| thermostat is open, replace cooling fan thermostat. |
|
|
| Cooling fan | Line voltage should now be at the cooling fan. If voltage |
|
|
|
| is present, check motor for opens, shorts or grounds. |
|
|
|
| With power off, check for locked rotor. |
|
| Oven will not heat | Main fan | If not operating, refer to “Oven fan will not run”. |
|
|
| Control transformer | Check for supply voltage to the primary of control |
|
|
|
| transformer. If no voltage is present, trace wiring back |
|
|
|
| to oven fan switch. If voltage is present, check for |
|
|
|
| 24VAC at transformer secondary. If there is primary |
|
|
|
| voltage, but no secondary voltage, replace control |
|
|
|
| transformer. |
|
|
| Air pressure switch | Check air switch terminals for supply voltage to |
|
|
|
| terminals “NO” and “COM”. If voltage is present on one |
|
|
|
| side only, check for air tube blockage or misalignment. |
|
|
|
| If these are okay, adjust air pressure switch or replace if |
|
|
|
| necessary. |
|
|
| Oven control | Check for 24VAC supply to oven control. If no voltage is |
|
|
|
| present, trace wiring back to control transformer. Check |
|
|
|
| for supply voltage to oven control. If no voltage is |
|
|
|
| present, trace wiring back to oven fan switch. If voltage |
|
|
|
| is present, check for a |
|
|
|
| is no |
|
|
|
| display. If there is a |
|
|
|
| the control to maximum temperature (see Installation |
|
|
|
| operation manual for temperature adjustment). With the |
|
|
|
| control at maximum temperature, check for supply |
|
|
|
| voltage to the mercury contactor. If there is voltage at |
|
|
|
| the mercury contactor, proceed to “Mercury contactor” |
|
|
|
| for next check. If there is no voltage at the mercury |
|
|
|
| contactor, trace wiring back to the oven control. If there |
|
|
|
| is no voltage output at the oven control, check the read- |
|
|
|
| out on the oven control. If the oven control reads |
|
|
|
| “PROBE FAIL” this indicates that the thermocouple has |
|
|
|
| failed or become disconnected from the oven control. |
|
|
| Thermocouple | Check to see that the thermocouple is securely |
|
|
|
| connected to the oven control. If the thermocouple is |
|
Impinger II – Advantage Digital Service Manual - International | 13 |