U.S. Fax 888 790-8193 Int’l Fax
Lincoln Foodservice Products, LLC
1111 North Hadley Road Fort Wayne, Indiana
United States of America Phone
SEQUENCE OF OPERATIONS IMPINGER II ADVANTAGE
SEQUENCE OF OPERATIONS IMPINGER II ADVANTAGE
MODEL 1164-000-EA
SERIAL NUMBER 2038616 TO
SCHEMATIC DIAGRAM MODEL 1154-000-EA, 1155-000-EA
SCHEMATIC DIAGRAM MODEL 1154-000-EA, 1155-000-EA
SERIAL NUMBER 2045408 AND ABOVE
SERIAL NUMBER 2038616 AND ABOVE
SCHEMATIC DIAGRAM MODEL 1164-000-EA
SCHEMATIC DIAGRAM MODEL 1164-000-EA
SERIAL NUMBER 2053336 AND ABOVE RoHS Compliant
TROUBLESHOOTING GUIDE IMPINGER II ADVANTAGE
Check for supply voltage to motor. WITH POWER OFF
Air pressure switch
Check air switch terminals for supply voltage to
This can be checked at motor connecting plug
necessary
Power supply
supply
2045408 & Above
wires in the motor connector. Frequency reading
for any type of damage to flame sensor wire and
Switch, conveyor reversing
switch as needed
TROUBLESHOOTING GUIDE IMPINGER II ADVANTAGE
achieved, proceed
Check to see that the thermocouple is securely
control at maximum temperature, check for supply
is no read-outon the oven display, replace oven
Thermocouple
load. Check the specification plate for rating
temperature reading but the oven will not heat
WITH POWER ON AND THERMOCOUPLE
Check the Amp draw on each power leg for proper
switch as needed
the motor connector. Frequency reading should be
before testing
Switch, conveyor reversing
IMPINGER II ADVANTAGE SERIES
REMOVAL, INSTALLATION AND ADJUSTMENTS
D.Disconnect power cord and remove fan
FUSE HOLDER - REPLACEMENT
THERMOSTAT, CONTROL BOX HI-LIMIT- REPLACEMENT
COOLING FAN, CONTROL BOX - REPLACEMENT
TEMPERATURE F
TRANSFORMER, CONTROL - REPLACEMENT
OVEN CONTROL - REPLACEMENT
THERMOCOUPLE - REPLACEMENT
H.Remove piping from gas valve
GAS VALVE - REPLACEMENT S/N 2045407 and Below
GAS VALVE - REPLACEMENT S/N 2045408 and Above
D.Remove the manual gas shut-offvalve
BYPASS ORIFICE - REPLACEMENT
TEMPERATURE REGULATION VALVE - REPLACEMENT
IGNITER/SENSOR ASSEMBLY - REPLACEMENT
D.Remove gas valve assembly.see “GAS VALVE”
D.Disconnect air tube from air pressure switch
A.Shut off power at oven switch
CAPACITOR, CONVEYOR DRIVE MOTOR - REPLACEMENT
AIR PRESSURE SWITCH - REPLACEMENT
IMPINGER II ADVANTAGE GENERAL VIEW
Page
1154-000-EA, 1155-000-EA
IMPINGER II ADVANTAGE CONTROL BOX
Page
IMPINGER II ADVANTAGE CONTROL BOX 1164-000-EA
Page
OVEN BACK ASSEMBLY
Page
CONVEYOR / DOOR