WARNING: Capacitor has a stored charge,

 

 

discharge before testing.

 

Switch, conveyor reversing

Check continuity between switch terminals. Replace

 

 

switch as needed.

 

 

 

 

Oven control

If there is 120VAC supplied to the motor, and the

 

 

motor, capacitor, and reversing switch check good,

 

 

replace the oven control.

Conveyor motor runs, but

NOTE: Display will indicate

 

there is no speed display

“Belt Jam”

 

 

Oven control

Check for output voltage from oven control to hall

 

 

effect sensor (sensor is located in conveyor motor).

 

 

Measure voltage at the motor connector, red wire

 

 

and yellow wire. Voltage should be approx. 10VDC. If

 

 

no voltage is present, trace wiring back to oven

 

 

control. If there is no voltage present at the oven

 

 

control, replace the oven control.

 

Conveyor motor

If there is voltage supplied to the hall effect sensor,

 

 

check for a frequency output from the hall effect

 

 

sensor. Measure frequency across the yellow and

 

 

white wires at the motor connector. Frequency

 

 

reading should be approx. 25 – 100 Hz. If these

 

 

readings are not achieved, replace conveyor motor. If

 

 

the readings are achieved, proceed.

 

Oven control

If the hall effect sensor readings are correct, but

 

 

there is no speed indicated on the display, replace

 

 

the oven control.