IMPINGER CONVEYOR OVENS
OVENS WITH PUSH BUTTON CONTROLS
SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, GAS
SEQUENCE OF OPERATION
IMPINGER II ADVANTAGE, ELECTRIC
OVENS WITH PUSH BUTTON CONTROLS
SCHEMATIC DIAGRAM
SCHEMATIC DIAGRAM
SCHEMATIC DIAGRAM
Page
SCHEMATIC DIAGRAM MODEL 1161-080-A
SCHEMATIC DIAGRAM MODEL 1162-080-A
SCHEMATIC DIAGRAM MODEL 1130-08H-A, 1131-08H-A
SCHEMATIC DIAGRAM MODEL 1132-08H-A, 1133-08H-A
TROUBLESHOOTING GUIDE GAS OVENS
exceeding temperature setting, check for proper
Terminals are normally closed. If open, reset
WITH POWER OFF Turn motor to check for locked
Centrifugal switch of burner
Power supply
the temperature control to the lowest setting
120VAC power supply
NOTE Check for proper ground connection on
the thermocouple chart located in the “Removal”
WITH POWER ON AND THERMOCOUPLE
maintenance may cause this problem. Also, most of
Power supply
TROUBLESHOOTING GUIDE ELECTRIC OVENS
1 PHASE
1 PHASE
1 PHASE
1 PHASE
timer, for more than 20 minutes, replace the
Contacts should open when main power switch is
NOTE On/ off operation of the main power switch
will set the timer to 20 minutes. If the timer is
WITH POWER ON AND THERMOCOUPLE
operations manual for temperature adjustment
to the thermocouple chart located in the
Check the Amp draw on each power leg for proper
most of the problems listed under “Oven will not
preventive maintenance may cause this. Also
Power supply
Check circuit breakers, reset if required. Check
IMPINGER II ADVANTAGE SERIES
REMOVAL, INSTALLATION AND ADJUSTMENTS
A.Shut off power at main breaker
CAPACITOR - REPLACEMENT
ON/OFF SWITCH - REPLACEMENT
A.Shut off power at main breaker
See “TRANSFORMER -BURNER- REPLACEMENT
NOTE Push reset button on new thermostat
A.Shut off power at main breaker
BURNER CONTROL - REPLACEMENT
GAS VALVE - REPLACEMENT
A.Shut off power at main breaker
A.Shut off power at main breaker
BYPASS ORIFICE - REPLACEMENT
MAIN BURNER ORIFICE - REPLACEMENT
A.Shut off power at main breaker
MERCURY CONTACTOR - REPLACEMENT
BEARING, CONVEYOR - REPLACEMENT
A.Shut off power at main breaker
C.Disconnect all wires and mark for reassembly
GENERAL VIEW IMPINGER II ADVANTAGE MODEL
GENERAL VIEW
1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1
CONTROL BOX, FRONT MODEL
1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1
CONTROL BOX, FRONT VIEW MODEL
CONTROL BOX, FRONT MODEL
CONTROL BOX, FRONT VIEW MODEL
1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1
CONTROL BOX, REAR MODEL
1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1
CONTROL BOX, REAR VIEW MODEL
CONTROL BOX REAR MODEL
CONTROL BOX, REAR VIEW MODEL
OVEN BACK ASSEMBLY
OVEN BACK ASSEMBLY VIEW
CONVEYOR / DOOR
CONVEYOR / DOOR VIEW