IMPINGER® CONVEYOR OVENS – MODEL SERIES 1400
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC
|
|
|
|
|
|
| Recommended Electrical | Agency | |
Model | Energy | Power | Voltage | Current | Phase | Hz | Specifications | Listing | |
Electric | 27 kW | 400/230 VAC | 40 Amps | 3 | 50 Hz | 5 Wires, 3 Poles | |||
|
|
|
|
|
|
|
| ||
1452 | Electric | 27 kW | 120/208 VAC | 80 Amps | 3 | 60 Hz | 5 Wires, 3 Poles | ||
|
|
|
|
|
|
|
| ||
1453 | Electric | 27 kW | 120/240 VAC | 70 Amps | 3 | 60 Hz | 5 Wires, 3 Poles | ||
|
|
|
|
|
|
|
| ||
1454 | Electric | 27 kW | 380/220 VAC | 41 Amps | 3 | 50 Hz | 5 Wires, 3 Poles | F | |
|
|
|
|
|
|
|
| ||
1455 | Electric | 27 kW | 415/240 VAC | 38 Amps | 3 | 50 Hz | 5 Wires, 3 Poles | F | |
|
|
|
|
|
|
|
|
|
|
| UTILITY SPECIFICATIONS REQUIRED – GAS |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Recommended |
|
|
| Agency | ||
|
|
|
|
|
|
|
|
|
|
|
| Electrical |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Listing | |||
Model | Energy | Power |
| Voltage | Current |
| Phase | Frequency | Specification | Gas |
| |||||||
|
|
|
|
| ||||||||||||||
Nat. Gas | 35 kW | 230 VAC | 3 Amps |
| 1 |
| 50 Hz | 3 Wires, 1 Pole | 35 kW/hr at 17.4 |
| ||||||||
|
| mB H2O column**** | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
L.P. Gas | 35 kW | 230 VAC | 3 Amps |
| 1 |
| 50 Hz | 3 Wires, 1 Pole | 35 kW/hr at 27.4 |
| ||||||||
|
| mB H2O column**** | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
1450 |
| Nat. Gas | 120,000 | 120 VAC | 5 Amps |
| 1 |
| 60 Hz | 3 Wires, 1 Pole | 120,000 BTU at 7 |
| ||||||
| BTU |
|
| inches H2O column**** |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
1451 |
| L.P. Gas | 120,000 | 120 VAC | 5 Amps |
| 1 |
| 60 Hz | 3 Wires, 1 Pole | 120,000 BTU at 11 |
| ||||||
| BTU |
|
| inches H2O column**** |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
1456 |
| Nat. Gas | 120,000 | 220/240 | 5 Amps |
| 1 |
| 50 Hz | 3 Wires, 1 Pole | 120,000 BTU at 7 |
| ||||||
| BTU |
| VAC |
|
| inches H2O column**** |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
1457 |
| L.P. Gas | 120,000 | 220/240 | 5 Amps |
| 1 |
| 50 Hz | 3 Wires, 1 Pole | 120,000 BTU at 11 |
| ||||||
| BTU |
| VAC |
|
| inches H2O column**** |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| A | B |
| C |
|
|
| D | E | F | G | H |
|
| |||
Agency |
| CSA | UL |
|
|
|
| MEA |
| AGA* | NSF |
| CE |
|
|
|
| |
Listing |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrical Supply for Australia:
Single Phase: 240VAC, 50Hz / 20 Amp: one neutral & one earth/ground.
Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.
* AGA Australian Gas Association | ** In Australia, use a 10 Amp General Purpose Outlet |
*** Reference Model Key |
|
All ovens require separate service and dedicated neutral.
GAS PRESSURE CONVERSION CHART
Inches of | KPa | Millimeters of | ||
Water Column | Water Column | |||
|
| |||
|
|
|
| |
3.5 | 0.87 | 8.70 | 88.9 | |
4.5 | 1.12 | 11.2 | 114.3 | |
7 | 1.74 | 17.40 | 177.8 | |
10 | 2.48 | 24.87 | 254.0 | |
10.5 | 2.61 | 26.11 | 266.7 | |
11 | 2.73 | 27.36 | 279.4 | |
14 | 3.48 | 34.81 | 355.6 | |
14.5 | 3.61 | 36.05 | 368.3 |
****NOTE: For proper operation, the gas valve requires a nominal inlet pressure of 7 inches H2O column for natural gas and 11 inches of H2O column for L.P. gas. A minimum inlet pressure of 1.0 inch of H2O above the manifold setting (NAT. manifold 3.5” H2O, L.P. manifold 10” H2O) must be maintained with no pressure drop from the no load to full load condition. The maximum inlet pressure must be maintained at or below ½ PSIG (14.5 inches H2O column). Refer to the chart on the left for pressure conversions.
Impinger I – 1000 Series Ops Manual | 5 |