Lincoln 1451 BURNER IGNITOR - REPLACEMENT 1. Shut off power at main breaker, Temperature, 10.4

Models: 1451 1450

1 24
Download 24 pages 46.14 Kb
Page 11
Image 11

BURNER IGNITOR - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove burner assembly. (SEE "BURNER ASSY.")

4.Remove pilot shield and pilot shield extension.

5.Remove burner ignitor.

6.Reassemble in reverse order (spark gap approx. .100 in. or 2.5 mm) NOTE: Be sure to reconnect burner ignitor cable to ignition control.

THERMOCOUPLE - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Slide thermocouple out of oven chamber.

NOTE: Remove conveyor and bottom fingers to aid in removal and installation of thermocouple.

4.Remove two (2) wires from temperature control. Make note of wire numbers or color and location for reinstallation.

5.Reassemble in reverse order making sure the metal end on the thermocouple is in the wire form in the oven chamber.

THERMOCOUPLE MEASURMENT

TEMPERATURE

D.C. MILLVOLTS (APPROX.)

200°

2.8

250°

4.0

300°

5.1

350°

6.0

400°

7.1

450°

8.2

500°

9.3

550°

10.4

600°

11.5

BURNER CONTROL TRANSFORMER - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Remove two (2) wires on primary side, note color and location.

4.Remove two (2) wires on secondary side, note color and location.

5.Remove two (2) screws from transformer base and replace assembly.

6.Reinstall in reverse order and check system operation.

CONTROL TRANSFORMER – REPLACEMENT

See “BURNER CONTROL TRANSFORMER – REPLACEMENT”

CONVEYOR DRIVE MOTOR - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Loosen set screw on conveyor drive sprocket and slide sprocket off shaft.

4.Disconnect motor plug.

5.Remove four (4) screws from motor frame, on control box side, and remove motor assembly.

6.Reassemble in reverse order making sure to align chain sprockets and adjust motor for proper chain tension (1/2" SAG).

Impinger I – 1450 Series Service Manual - Domestic

11

Page 11
Image 11
Lincoln 1451 BURNER IGNITOR - REPLACEMENT 1. Shut off power at main breaker, Remove control panel top and front cover