 SAFETY PRECAUTION

The machine is adaptive in following situation SAFETY PRECAUTION

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

Indoor

Maximum: D.B / W.B

32 C / 23 C

 

Minimum:

D.B / W.B

18 C / 14 C

Cooling

 

 

 

 

 

Outdoor

Maximum:

D.B / W.B

43 C / 26 C

 

 

Minimum: D.B

15 C

 

 

 

 

 

 

 

 

Indoor

Maximum:

D.B

27 C

 

Minimum:

D.B

15 C

Heating

 

 

 

 

 

 

Outdoor

Maximum:

D.B / W.B

24 C / 18 C

 

Minimum: D.B / W.B

-7 C / -8 C

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T. 3.15A /250V.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self-provided. The power cable should be H07RN-F 5G2.5mm2 (for HDU-42H03/H) or H07RN-F 3G4.0mm2 (for HDU-24H03/H, HDU-28H03/H). The connecting cable should be H05RN-F 4G0.75mm2.

All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.

7.The indoor unit installation height is at least 2.5m.

5

Page 6
Image 6
Haier HDU-24H03/H, HDU-42H03/H, HDU-28H03/H Safety Precaution, The machine is adaptive in following situation

FAQ

What should I do if the supply cord is damaged?

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

What type of fuse should I use if the fuse on the PC board is broken?

If the fuse on the PC board is broken, please change it with the type T.3.15A /250V.

What should the breaker of the air conditioner be?

The breaker of the air conditioner should be an all-pole switch, and the distance between its two contacts should be no less than 3mm.