TROUBLESHOOTING GUIDE
IMPINGER ADVANTAGE GAS OVENS SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming power supply | Check circuit breaker, reset if required. Check power |
|
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power, call power co. if needed. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Switch, oven power | Check for 120VAC supply to switch. If no voltage is |
|
| present, trace wiring back to fuse holder. Check |
|
| continuity between switch terminals. Replace switch as |
|
| needed. |
| Motor, main fan | Check for 120VAC supply to the motor. If no voltage is |
|
| present, trace wiring back to the switch. Check motor |
|
| for opens, shorts or grounds. |
|
| WITH POWER OFF: Turn fan blade to check for locked |
|
| rotor. |
No control box cooling | Incoming power supply | Check circuit breaker, reset if required. Check power |
|
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power, call power co. if needed. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Switch, oven power | Check for 120VAC supply to switch. If no voltage is |
|
| present, trace wiring back to fuse holder. Check |
|
| continuity between switch terminals. Replace switch as |
|
| needed. |
| Cooling fan | Check for 120VAC supply to the cooling fan. If no |
|
| voltage is present, trace wiring back to the oven power |
|
| switch. If voltage is present and motor does not run, |
|
| check for opens, shorts or grounds. |
|
| WITH POWER OFF: Check for locked rotor. |
No automatic control | Incoming power supply | Check circuit breaker, reset if required. Check power |
box cooling |
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power. Call power co. if needed. |
| Cooling fan thermostat | Check cooling fan thermostat (thermostat closes at |
|
| 120°F and opens at 100°F). With cooling fan |
|
| thermostat |
|
| thermostat is open, replace cooling fan thermostat. |
Control box cooling | Cooling fan thermostat | See “Cooling fan thermostat” (NOTE: Thermostat will |
fan continues to run |
| remain closed if control box temperature remains |
|
| above 120°F. |
Oven will not heat | Main fan | If not operating, refer to “Oven fan will not run”. |
| Gas supply | Check for adequate gas supply to oven. |
| Centrifugal switch of main fan | Check for 120VAC at wire #5 (input to centrifugal |
| motor | switch, located at |
|
| near main fan motor) to neutral. If no voltage is present, |
|
| trace wiring back to oven power switch. If voltage is |
|
| present, check for 120VAC at wire #9 (output of |
|
| centrifugal switch) to neutral. If no voltage is present at |
|
| wire #9, and the motor is running, replace the main fan |
|
| motor. |
| Burner blower motor | Check for 120VAC supplied to burner blower motor. If |
|
| no voltage is present, trace wiring back to primary of |
|
| control transformer. If voltage is present and motor is |
4 |
| Impinger I – 1450 Series Service Manual - Domestic |