Lincoln Series 1200, Series 1000 service manual

Models: Series 1000 Series 1200

1 112
Download 112 pages 35.42 Kb
Page 49
Image 49

 

Temperature Control

Check for 120 VAC across L1 and L2 on

 

 

temperature control board. If no voltage is present,

 

 

retrace wiring back to power supply. Turn the

 

 

temperature adjustment knob to the maximum

 

 

temperature position and check for 120 VAC at the

 

 

load terminal to neutral. If 120 VAC is not present,

 

 

proceed as follows: If 120 VAC is present and unit

 

 

is not heating, see "Solenoid Valve."

 

Thermocouple Probe

Remove thermocouple leads from the temperature

 

 

control board and measure the millivolt output of

 

 

these leads. Refer to chart on page 59 for proper

 

 

readings. If the thermocouple probe checks good,

 

 

then the problem is usually with the temperature

 

 

control board.

 

Solenoid Valve

If output voltage is present at temperature control

 

 

board, check for voltage at solenoid valve. If

 

 

voltage is present, listen for valve to open and

 

 

close. Also check for opens, shorts in coil. Replace

 

 

as needed.

Indicator light is on,

Temperature Control

Check for 120 VAC across L1 and L2 on

but no main flame

 

temperature control board. If no voltage is present,

(1033-1034)

 

retrace wiring back to power supply. Turn the

 

 

temperature adjustment knob to the maximum

 

 

temperature position and check for 220 VAC at the

 

 

load terminal to neutral. If 220 VAC is not present,

 

 

proceed as follows: If 220 VAC is present, and unit

 

 

is not heating, see "Flame Monitor". Check for 220

 

 

VAC at terminal "COM" on temperature control

 

 

board. If no voltage is present, trace wiring back to

 

 

ignition control.

 

Thermocouple Probe

Remove thermocouple leads from the temperature

 

 

control board and measure the millivolt output of

 

 

these leads. Refer to chart on page 59 for proper

 

 

readings. If the thermocouple probe checks good,

 

 

replace temperature control.

 

Flame Monitor

Check for 220 VAC at terminal #1. If no voltage is

 

 

present, trace wiring back to temperature control.

 

 

Check for 220 VAC output at terminal #8. NOTE:

 

 

There is a delay of up to 2 seconds for 220 VAC

 

 

output at terminal #8. If there is no voltage output

 

 

at terminal #8, check the reset button. Replace

 

 

control as needed.

 

Relay, Main Burner

Check for 220 VAC at relay coil, if no voltage is

 

 

present, trace wiring back to flame monitor. Check

 

 

for 120 VAC to relay contacts. If no voltage is

 

 

present, trace wiring back to power supply. Check

 

 

to ensure contacts are closing. Replace relay as

 

 

needed.

 

Valve, Temperature

Check for 120 VAC at valve, if no voltage is

 

Regulation

present, trace wiring back to relay. If voltage is

 

 

present, listen for valve to open and close. Check

 

 

for opens or shorts in coil. Replace as needed.

Impinger I -–1000 Series Service Manual - International

49

Page 49
Image 49
Lincoln Series 1200, Series 1000 service manual

Series 1000, Series 1200 specifications

The Lincoln Series 1200 and Series 1000 are two distinguished models in the range of Lincoln Electric welding machines, epitomizing quality, versatility, and advanced technology for both industrial and residential welding applications.

The Lincoln Series 1200 is renowned for its robust build and high-performance capabilities. One of its main features is the ability to perform both MIG (Metal Inert Gas) and stick welding processes, making it a versatile option for various welding requirements. It incorporates an intuitive control panel that allows for easy settings adjustments, ensuring operators can swiftly adapt to different materials and thicknesses. The Series 1200 is equipped with a powerful drive system to provide smooth wire feeding, minimizing downtime due to jams or misfeeds. Additionally, its high-duty cycle support allows continuous operation, making it an ideal choice for professional welders and fabrication shops.

In terms of technology, the Series 1200 employs advanced inverter technology that enhances energy efficiency while reducing the machine’s overall weight. This results in portability without compromising power, making it a practical choice for on-site tasks. Moreover, the machine features an automatic voltage adjustment that optimizes performance based on the input voltage, ensuring reliable operation even under fluctuating power conditions.

On the other hand, the Lincoln Series 1000 is specifically designed for entry-level users and small projects. It shines with its user-friendly interface, which simplifies the welding process for beginners. This model typically includes pre-set parameters and an easy-to-read display, enabling novice operators to achieve excellent welds with minimal experience. Despite its entry-level focus, the Series 1000 does not skimp on performance, offering dependable results across various materials.

Both the Series 1200 and Series 1000 incorporate safety features, including thermal overload protection, ensuring that users can operate the machines with peace of mind. Their durable construction allows for prolonged use in tough work environments without sacrificing reliability.

In conclusion, the Lincoln Series 1200 and Series 1000 cater to a wide range of welding needs, from professional applications to home projects. Their respective features and technologies present options that can fit various skill levels while delivering exceptional welding performance and longevity. Whether you are a seasoned professional or a hobbyist, Lincoln Electric provides reliable solutions to meet your welding requirements.