A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS – IDEALARC CV-250

INPUT - THREE PHASE ONLY

Standard

Voltage

208/230/460/3/60

230/460/575/3/60

Duty Cycle

100% Duty Cycle

NEMA Class I (100)

60% Duty Cycle

100% Duty Cycle

Welding Current/Voltage Range

(Continuous)

30A/7V - 300A/32V

DC

Efficiency at 100% Load

72%

Idle Power

800W

Input Current at

Rated Output

100% Duty Cycle 56/51/26

60% Duty Cycle 62/56/28

100% Duty Cycle 51/26/20

60% Duty Cycle 56/28/22

RATED OUTPUT

Amps

250

300

250

OUTPUT

Normal Open Circuit Voltage

10-43

MAX OCV: 50

MISC. INFORMATION

Input kVA

60% Load - 22.3

100% Load - 20.3

Power Factor at 100% Load

.53

Code

Number

10013

10014

Volts at Rated Amperes

30

32

30

Auxiliary Power

42 Volts AC, 10 Amps

115 Volts AC, 5 Amps

( Both Circuit Breaker Protected)

Idle Current - Amps

11/10/5

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

21.5 in.

19.5 in.

27.0 in.

300 lbs

 

(Lift bail, add 3.12 in)

 

546 mm

495 mm

686 mm

(137 kg)

 

 

(Lift bail, add 80 mm)

 

 

CV-250

Page 8
Image 8
Lincoln Electric manual Installation, Technical Specifications Idealarc CV-250