LINCOLN

 

POWER SOURCE

N.D.

 

 

14 PIN

 

AMPHENOL

 

LN-742

 

WIRE

WARNING

ELECTRIC

SHOCK

CAN KILL

Turn off (0) the power switch on the Welding Power Source before connecting the wire feeder.

Only qualified persons should install, use or service this machine.

F-8

CV-400-I

+ -

FEEDER

 

TO WORK

 

LN-742

 

 

ELECTRODE CABLE

 

INPUT CABLE

 

 

ASSEMBLY

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE AND SET WIRE FEEDER VOLTMETER POLARITY SWITCH ON POWER SOURCE TO PROPER POLARITY.

N.C. PINS NOT LISTED ARE NOT CONNECTED ON CABLE.

N.D. IF USING K589-1, REMOTE CONTROL KIT,

SET POWER SOURCE CONTROL SWITCH TO "REMOTE" POSITION.

DIAGRAMS

FUNCTIONS ARE LISTED FOR REFERENCE ONLY AND EACH MAY OR MAY NOT BE PRESENT IN YOUR EQUIPMENT.

(SEE APPROPRIATE WIRING DIAGRAM)

PIN

LEAD

FUNCTION

C

2

TRIGGER CIRCUIT

D

4

TRIGGER CIRCUIT

E77 OUTPUT CONTROL

F

76

OUTPUT CONTROL

G75 OUTPUT CONTROL

H 21 WORK

I41 42V AC

K

42

42V AC

 

K=42

 

I=41

 

H=21

C=2

 

D=4

G=75

 

E=77F=76

14-SOCKET BOX RECEPTACLE, FRONT VIEW AND 14-PIN CABLE PLUG, REAR VIEW

K=42

I=41

 

C=2

 

H=21

 

 

 

 

1-28-94

G=75

D=4

S20409

 

 

F=76

E=77

 

14-SOCKET BOX RECEPTACLE, REAR VIEW AND 14-PIN CABLE PLUG, FRONT VIEW

LINCOLN POWER SOURCE TO AN LN-742

F-8

Page 36
Image 36