A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS – IDEALARC CV-400-I

INPUT - THREE PHASE ONLY

Standard

Voltage

220/380/440/3/50/60

230/400/3/50/60

380/500/3/50/60

415/3/50/60

200/400/3/50/60

Duty Cycle

NEMA Class II (60)

100% Duty Cycle

IEC 974-1 60%

100% Duty Cycle

Welding Current/Voltage Range

(Continuous)

50A/7V - 400A/37V

DC

Efficiency at 100% Load

NEMA Rated 78%, IEC Rated 68%

Idle Power

825W

Input Current at

Rated Output

100% Duty Cycle 60/35/30

60% Duty Cycle 62/36/31

100% Duty Cycle 58/34

60% Duty Cycle 60/33

100% Duty Cycle 35/26

60% Duty Cycle 36/27

100% Duty Cycle 32

60% Duty Cycle 33

100% Duty Cycle 66/33

60% Duty Cycle 68/34

RATED OUTPUT

Amps

400

300

400

300

OUTPUT

Normal Open Circuit Voltage

10-43

MAX OCV: 50

Input kVA

NEMA 60% Load - 23.6, IEC 60% Load - 23.2 NEMA 100% Load - 22.9, IEC 100% Load - 23.2

MISC. INFORMATION

Power Factor at Rated Load

.80

Power Factor at 100% Load

.55

Code

Number

10183 (Export, NEMA Rated)

10182 (European, IEC Rated)

10184 (Export, NEMA Rated)

10185 (Export, NEMA Rated)

10186 (Export, NEMA Rated)

Volts at Rated Amperes

36

32

34

29

Auxiliary Power

42 Volts AC, 10 Amps

115 Volts AC, 5 Amps (Except Code 10182)

220 Volts AC, 2 Amps

( All Circuit Breaker Protected)

Idle Current - Amps

16/9/8

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

21.5 in.

19.5 in.

27.0 in.

 

 

(Lift bail, add 3.12 in)

 

300 lbs

 

 

 

(137 kg)

546 mm

495 mm

686 mm

 

 

(Lift bail, add 80 mm)

 

 

 

 

 

 

CV-400-I

Page 8
Image 8
Lincoln Electric manual Installation, Technical Specifications Idealarc CV-400-I