INSTALLATION | ||
|
|
|
FUEL
USE DIESEL FUEL ONLY-
Low Sulphur fuel or ultra low sulphur fuel in USA and CANADA only.
WARNING
•Fill the fuel tank with clean, fresh fuel. The capacity of the tank is 20 gals. (75.7 ltrs). When the fuel gauge reads empty the tank contains approximately 2 gals. (7.6ltrs.) of reserve fuel.
NOTE: A fuel shut off valve is located on the
ENGINE COOLING SYSTEM
WARNING
Air to cool the engine is drawn in the side and exhaust- ed through radiator & case back. It is important that the intake and exhaust air is not restricted. Allow a mini- mum clearance of 1ft. (0.6m) from the case back and 16 in. (406mm) from either side of the base to a vertical surface.
BATTERY CONNECTION
CAUTION
Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.
The DX450 is shipped with the negative battery cable dis- connected. Make certain that the
NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the bat- tery with the correct polarity. (See Battery in “Maintenance Section”)
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction. Tighten using a 9/16"(14mm) socket or wrench.
SPARK ARRESTER
Some federal, state or local laws may require that gasoline or diesel engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard.
The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the
WARNING
An incorrect spark arrestor may lead to damage to the engine or adversely affect performance.
REMOTE CONTROL
The DX450 is equipped with a
When in TOUCH START TIG mode and when a Amptrol is connected to the
When in the DOWNHILL PIPE mode and when a remote control is connected to the
EXAMPLE: When the OUTPUT CONTROL on the welder is set to 200 amps the current range on the remote control will be
In the
The
WARNING
NOTE: When a wire feeder with a built in welding voltage control is connected to the