INSTALLATION |
Read entire Installation Section before installing the PLASMA 20.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK CAN KILL.
•Only qualified personnel should perform this installation.
•Only personnel that have read and understood the PLASMA 20 Operating Manual should install and operate this equipment.
•Machine must be plugged into a receptacle which is grounded per any national, local or other applicable electrical codes.
•The PLASMA 20 power switch is to be in the OFF (“O”) position when installing work cable and gun and when connecting power cord to input power.
___________________________________________
SELECT PROPER LOCATION
Place the PLASMA 20 where clean cool air can freely circulate in and out the front, rear and side louvers. Dirt, dust, smoke, gas or any foreign material that can be drawn into the machine should be kept at a mini- mum. Insure open space of at least 15 ft. around the machine. Failure to observe these precautions can result in excessive operating temperatures and nui- sance shutdown of the machine.
STACKING
The PLASMA 20 cannot be stacked.
TILTING
The PLASMA 20 must be placed on a stable, level surface so it will not topple over.
HIGH FREQUENCY INTERFERENCE PROTECTION
The PLASMA 20 employs a touch start mechanism for arc initiation which eliminates high frequency emis- sions from the machine as compared with spark gap and solid state type high frequency generators. Keep in mind, though, that these machines may be used in an environment where other high frequency generat- ing machines are operating. By taking the following steps, high frequency interference into the PLASMA 20 can be minimized.
(1)Make sure the power supply chassis is connected to a good earth ground. The work terminal ground does NOT ground the machine frame.
(2)Keep the work clamp isolated from other work clamps that have high frequency.
(3)If the work clamp cannot be isolated, then keep the clamp as far as possible from other work clamp connections.
(4)When the machine is enclosed in a metal building, several good earth driven electrical grounds around the periphery of the building are recom- mended.
Failure to observe these recommended installation procedures may cause improper function of the PLAS- MA 20 or possibly even damage to the control system or power supply components.
INPUT ELECTRICAL CONNECTIONS
The PLASMA 20 must be connected to a
The PLASMA 20 is rated for 115VAC input.
Use on 15 amp branch circuits will limit cutting output. When the output is set at 16 amps or greater, the input fuse or circuit breaker may “blow” in roughly 30 seconds or less (depending on fuse or circuit breaker type).
To achieve
WARNING
•Failure to wire as instructed may cause personal injury or damage to equipment.
•To be installed or checked by an electrician or qualified person only.
PLASMA 20