A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - PLASMA 20

INPUT - SINGLE PHASE

Standard Voltage

115/1/50/60Hz (15 Amp Branch)

115/1/50/60Hz (20 Amp Branch with 20 Amp Plug*)

1Ø Input Current at Rated Output

115 V: 20A @ 50%

115 V: 26A @ 40%

RATED OUTPUT

 

 

 

 

 

 

Duty Cycle

 

 

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50% on 115V (15 Amp Branch)

 

 

 

 

 

 

15 A

 

40% on 115V (20 Amp Branch with 20 Amp Plug*)

 

20 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

Current

 

 

 

Open Circuit

Pilot Current

 

 

 

Range

 

 

 

Voltage

 

 

 

 

 

10-20 Amps

 

 

 

310 VDC

17 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REQUIRED AIR FLOW

RATE

 

 

REQUIRED AIR

INLET PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5 cu. ft./min.

 

 

 

 

 

 

72.5 to 150 PSI

 

 

 

 

 

 

(100L/min.)

 

 

 

 

 

( 5 Bar TO 10.3 Bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMEND INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

For all plasma cutting applications

 

 

 

 

 

 

 

 

Based on U.S. National Electrical Code

 

 

 

 

 

 

Ambient Temperature 30oC or Less

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

AC Input

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

Time-Delay

 

Type SJT or Hard Usage

 

 

 

at

 

 

Plug Size

 

 

Circuit Breaker

 

Input Cord

 

 

 

50/60

 

 

 

 

 

 

 

or Fuse Size

 

 

 

 

 

 

Hertz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 A

 

115V-1Ø

 

 

 

 

 

20 AMPS

 

 

 

 

 

 

5-20P*

 

 

3 Conductor, #14 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 A

 

115V-1Ø

 

 

5-15P

 

 

 

15 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

12in.

305 mm

Width

6in.

152 mm

Depth

16in.

406mm

Weight

Including

Torch Cable

21lbs.

9.5 kg.

*5-20P plug must comply with the standard for attachment plugs and receptacles, UL498.