C-3

 

ACCESSORIES

C-3

 

 

 

 

 

 

K226 CONTACT ASSEMBLY

Maintenance

- Rusty or dirty wire and/or exces-

The K226 assemblies are used for welding at currents

sively high welding currents increase wear on the

contact jaws. When arcing occurs or the elec-

from 600 to 1000 amps.

trode becomes loose in the jaws, remove the

Model K226-T

- (2 tapered jaws)

jaws and ʻdressʼ them with a file. When neces-

 

3/32” and 1/8” (2.4 and 3.2mm) electrode

sary, the jaw inserts should be replaced.

Model K226-R- (1 tapered and 1 rectangular jaw)

NOTE: Units made prior to 1979 did not have

 

1/8” thru 7/32” (3.2 - 5.6mm) electrode

 

inserts. The replacement jaws will have

Installation -

Remove the two nozzle mounting

 

them.

 

clamps from the wire drive. Insert the outgoing

The contact jaws must be kept in line with the

wire guide from the wire feed head into the top of

wire guide. Align the jaws as follows: (See Figure

the K226 and install the assembly in position on

C.3)

 

the bottom of the wire feed head. Use the two

1.

Loosen the stationary contact jaw screws.

screws provided with the K226 to attach it to the

wire drive. See Figure C.3.

2.

Release the tension on the moveable jaw by

NOTE: Removing the 4 screws that hold the noz-

 

loosening the screws holding the spring.

 

zle body to the mounting block allows the

3

Place a straight 14” (or longer) piece of bare

 

nozzle to be rotated to any of four posi-

 

tions 90° apart. See Figure C.3.

 

5/32” (4.0mm) wire through the wire guide

Connect two (2) electrode cables to the contact

 

and into the drive rolls of the feed head.

jaws (one under each 1/2-13 nut. Make sure that

4. Adjust the stationary contact so the wire

the cable lugs are flat against the copper and

 

touches the jaw at the center of the groove

tighten the nuts securely. See Figure C.3.

5.

for the entire length of the jaw.

Slip the rubber flux hose that comes with the

Tighten the screws, remove the wire and re-

K226 on to the flux hopper valve. Fit the copper

 

tighten the screws holding the spring to

tube into the other end and place it in the clip on

 

apply tension to the moveable jaw. The

the lower jaw assembly. See Figure C.3.

 

moveable jaw should move freely when fin-

 

 

 

 

ished.

 

FIGURE C.3 - K226 CONTACT NOZZLE ASSEMBLY

Use to Mount to Wire Drive

Remove(4)

Screws to

Rotate Nozzle

Attach Weld Cables Here

 

Stationary

Spring

Contact

 

Moveable

 

Contact

 

K226-R

Flux

Only

Hose

Copper Tube

WORK NOZZLE

TRAVEL TRAVEL

MAXSA™ 22 & 29 WIRE DRIVES