TOOL ASSEMBLY

WARNING!

To reduce the risk of injury, always unplug tool before attaching or removing accessories or mak- ing adjustments. Use only specifically recom- mended accessories. Others may be hazardous.

Assembling Dymorigs & Vac-U-Rig® Stands

For Cat. No. 4125 & 4130 only (Fig. 1).

Fig. 1

Handle

spoke

Cradle assembly

Column

Hex bolt

Base

Leveling screws (4)

Socket set

Column bolts

screws (2)

1.Set the base on the ground. Loosen the hex bolt and nut (wrench not supplied). Raise the column upright.

2.To core vertically or horizontally, insert the large column bolt (provided in separate accessory bag) through the bottom of column and into the base. Tighten hex bolt and nut (wrench not supplied).

To angle core, tilt the column to the desired angle and tighten the hex bolt and nut. Save the column bolt for future use when vertical or horizontal coring.

3.Tighten the two (2) black socket set screws located on the base with the supplied wrench.

4.Screw the four (4) handle spokes (provided in separate accessory bag) into the hub on the cradle assembly.

For Cat. No. 4115 & 4120 only (Fig. 2).

Fig. 2

Cradle

assembly

 

Handle spoke

 

Column

Base

Leveling

screws (4)

 

 

Column

 

bolts (2)

 

Lock washers

1.Set the base on the ground.

2.Remove two (2) bolts and two (2) lockwashers from accessory bag.

3.Place the column in the slot of the base.

4.Insert two (2) bolts and two (2) lockwashers and tighten securely. page 6

Moving the Handle to the Other Side

For Cat. Nos. 4125 & 4130 only (Fig. 3).

Fig. 3

Bubble

Socket

level Socket

screws (4)

screw

Ammeter gauge

Meter box

Cradle

Cradle

 

lock

1.Tighten the cradle lock.

2.Loosen the socket head screw and remove the meter box.

3.Remove four (4) socket head screws holding the spoked handle housing.

4.Turn the assembly around 180°.

5.Replace the four (4) socket head screws and tighten securely.

6.Attach meter box to opposite side (see "Mounting the Meter Box"). For Cat. Nos. 4115 & 4120 only (Fig. 4).

Fig. 4

Socket screw

and washer Socket

 

 

screw

Ammeter gauge

Meter box

Cradle

1.Loosen the cradle lock.

2.Raise the cradle to the maximum height.

3.Lift the cradle an additional 1/2" by hand.

4.Tighten the cradle lock.

5.Loosen the socket head screw and remove the meter box.

6.Remove the meter box stud from the cradle.

7.Remove the screw and washer from the end of the pinion shaft.

8.Remove the handle and pinion shaft assembly.

9.Turn the assembly around 180° and insert into cradle.

10.Replace the screw and washer and tighten securely.

11.Replace the meter stud on the side opposite the handle.

12.Attach meter box to opposite side (see “Mounting the Meter Box”).

13.Loosen the cradle lock and lower the cradle until the pinion engages the rack.

14.Tighten the cradle lock.

Page 6
Image 6
Milwaukee 4097-20 15A, 58-14-3005d9, 4125, 4092-20 15A, 4120, 4094 20A, 4115 Tool Assembly, Moving the Handle to the Other Side