b-4

OPERATION

b-4

 

 

 

3. TRIGGER CONNECTOR

There is one circular connector for the gun trigger on the front of the LN-25 PRO. Note – if the gun trigger is already depressed when the feeder is powered up, the feeder will not activate. Release and then press the gun trigger to begin welding.

The 83% wire feed speed reduces the wire feed speed to 83% of the original set value when activated. For example, if the original wfs = 200 in/min, the feed- er will regulate to 0.83 x 200 = 166 in/min.

The 83% trigger requires a gun with a dual procedure switch.

This feature is often useful when welding pipe, and a “cooler” procedure is required on the bottom portion.

 

 

Function

Pin

Wiring

 

 

 

 

 

 

 

 

C

B

5-pin trigger

 

A

5 volt supply

 

E A

connector for

B

Not used

D

push-guns

C

Trigger

 

 

only.

D

83% WFS switch

 

 

 

 

E

5 volt supply

 

 

 

 

 

 

4. WORK SENSE LEAD

Always turn power off at the welding power source before moving the work sense lead.

The work sense lead attaches to the item being weld- ed.

5. SET-uP PuShbuTTON

before entering the set-up menu:

Calibration of Wire Feed Speed:

Set the display to the desired wire feed speed (example: 400 inches per minute)

Measure the actual wire feed speed (example: 405 inches per minute)

Place the WFS knob in the 12 o’clock position.

To enter the set-up menu, use paper clip to press the small button located on the case front.

PUSHBUTTON

WIRE FEED SPEED uNITS

To change the wire feed speed units:

Rotate the WFS knob to the left to use “inches/minute” for the wire feed speed units.

Rotate the WFS knob to the right to use “meters/minute” for the wire feed speed units.

Then rotate the WFS knob to the 12 o’clock position.

US

EUro

Press the set-up button again to enter WFS calibration.

WFS CALIbRATION

Measurements for adjusting the WFS calibration must be made before entering the set-up menu. If no changes are being made to the calibration, then press the set-up button to enter WFS Knob Range.

While in the set-up menu, adjust the calibration factor in the following example:

Actual WFS

= Caibration Factor

Example:

405

= 1.01

Set WFS

400

 

Press the set-up button when calibration factor is set.

RED-D-ARC LN-25™ PRO EXTREME