Lincoln Electric IM10084 manual WFS Calibration, Run-In

Models: IM10084

1 38
Download 38 pages 6.35 Kb
Page 21
Image 21

B-5

OPERATION

B-5

 

 

 

Wire Feed Speed Units

To change the wire feed speed units:

Rotate the WFS knob to

 

the

left

to

use

 

“inches/minute” for the

 

wire feed speed units.

US

 

O O A

V

 

 

 

LN™-25 IRONWORKER

 

 

 

O O WFS

 

To change the Run-in setting:

Rotate the WFS knob to the left to turn Run-In OFF.

Rotate the WFS knob to the right to turn Run-In ON.

r un OFF

O O

A

V

LN™-25 IRONWORKER

O O WFS

Rotate the WFS knob to the right to use “meters/minute” for the wire feed speed units.

Then rotate the WFS knob to the 12 oʼclock position.

EU ro

O O

A

V

LN™-25 IRONWORKER

O O WFS

 

r u n

On

Then rotate the WFS knob

O O A

V

 

 

to the 12 oʼclock position.

LN™-25

IRONWORKER

 

 

 

O O WFS

 

Press the set-up button

again to enter the WFS calibration menu.

Press the set-up button again to enter the Run-In menu.

RUN-IN

“Run-in” refers to the wire feed speed during the time from when the trigger is pulled to when an arc is struck.

When Run-in is “ON”, the wire feed speed is reduced until an arc is struck. Factory setting is Run-In “OFF”.

Model

Run-in Wire Feed Speed

Extra Torque Models

25 in/min

Standard Speed Models

50 in/min

 

 

When Run-in is “OFF”, the wire feed speed is the same as the welding wire feed speed. Turn Run-In “OFF” for fast, crisp starts, especially when running with .035 or .045 (0.9 or 1.2mm) solid steel wires at high wire feed speeds.

WFS CALIBRATION

Measurements for adjusting the WFS calibration must be made before entering the set-up menu. If no changes are being made to the calibration, then press the set-up button to enter WFS Knob Range.

While in the set-up menu, adjust the calibration factor as follows:

Actual WFS

=Calibration Factor Example

405

=1.01

Set WFS

400

Press the set-up button when calibration factor is set.

LN-25™ IRONWORKER