Lincoln Electric IM10084 manual Troubleshooting

Models: IM10084

1 38
Download 38 pages 6.35 Kb
Page 33
Image 33

E-4

TROUBLESHOOTING

E-4

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Output Problems

 

7.

Incorrect tension arm pressure on

7.

Adjust the tension arm per the

 

 

the drive rolls.

 

Instruction Manual.

Most elec-

 

 

 

 

trodes feed well at a tension arm

 

 

 

 

setting of "3".

 

 

8.

The spindle brake is too tight.

8.

Verify the spool of wire moves

 

 

 

 

with minimal effort.

 

 

9.

Worn drive roll.

9.

Replace the drive rolls if worn or

 

 

 

 

filled with dirt.

 

 

 

 

 

 

 

 

Wire feed speed consistently oper-

1.

The jumper lead for normal

1.

Properly

connect

the normal

ates at the wrong value. The speed

 

speed/extra torque is connected

 

speed/extra torque jumper.

changes when the wire feed speed

 

improperly.

2.

Install the proper pinion gear in

knob is adjusted.

2.

The wrong gear is installed in the

 

the wire drive.

 

 

 

wire drive.

3.

Replace

the motor/gearbox

 

3. The brushes on the motor are

 

assembly.

 

 

 

 

worn.

 

 

 

 

 

 

 

 

 

The wire feed speed stuck at 200-

1.

The tachometer is connected

1.

Verify all of the tachometer leads

300 in/min and there is no change

 

improperly.

 

are properly connected.

when the wire feed speed knob is

2.

The tachometer has failed.

2.

Replace the motor and tachome-

adjusted.

 

 

 

ter assembly.

 

 

 

 

 

Variable or "hunting" arc.

1.

Wrong size, worn and/or melted

1. Replace the contact tip.

 

 

contact tip.

 

 

 

 

 

2.

Worn work cable or poor work

2.

Verify all work and electrode con-

 

 

connection.

 

nections are tight and that the

 

 

 

 

cables are in good condition.

 

 

 

 

Clean/replace as necessary.

 

3.

Wrong polarity.

3.

Adjust polarity to the recommend-

 

 

 

 

ed procedure.

 

 

4.

The gas nozzle is extended

4.

Adjust the gas nozzle and shorten

 

 

beyond the contact tip or the wire

 

the strike out to 3/8 to 1/2 inches.

 

 

stickout is too long.

 

 

 

 

 

5.

Poor gas shielding on processes

5.

Check gas flow and mixture.

 

 

requiring gas.

 

Remove or block sources of

 

 

 

 

drafts.

 

 

 

 

 

When the trigger is pulled, the wire

The Run-In switch is “ON”

Use the set-up Push-button to turn

feeds slowly.

 

 

Run-in OFF.

 

 

 

 

 

Poor arc starts with sticking or

1. Improper procedures or tech-

1. See "Gas Metal Arc Welding

"blast-offs", weld porosity, narrow

 

niques.

 

Guide" (GS-100).

 

and ropy looking bead.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

LN-25™ IRONWORKER

Page 33
Image 33
Lincoln Electric IM10084 manual Troubleshooting