REAR CONTROLS:

1

2

3

ITEMDESCRIPTION

1Gas Purge Pushbutton

2 Shielding Gas Inlet

3 Electrode Lead

GAS PURGE PUSHBUTTON

The gas solenoid valve will energize but neither the power source output nor the drive motor will be turned on. The Gas Purge switch is useful for setting the proper flow rate of shielding gas. Flow meters should always be adjusted while the shielding gas is flowing.