14 Troubleshooting

14 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

A. Standing Pilot Ignition System

Symptom

Possible Causes

Corrective Actions

 

 

 

1. After repeated

a. Defective ignitor.

Check the spark at the electrode and pilot. If no spark and electrode wire

triggering of the

 

is properly connected, replace the ignitor.

red or black piezo

 

 

ignitor button, the

 

 

b. Defective pilot

Using match, light the pilot. If the pilot lights, turn off the pilot and trigger

spark ignitor will not

or misaligned

the red piezo ignitor button again. If the pilot lights, an improper gas/air

light the pilot.

electrode (spark at

mixture caused the bad lighting and a longer purge period is recom-

 

 

electrode).

mended. If the pilot will not light, ensure the gap at the electrode and pilot

 

 

is one-eighth (1/8) inch to have a strong spark. If the gap is OK, replace

 

 

the pilot.

 

c. No gas or low

Check the remote shut-off valves from the fireplace. Usually, there is a

 

gas pressure.

valve near the gas main. There can be more than one (1) valve between

 

 

the fireplace and the main.

 

d. No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

 

 

 

2. The pilot will not

a. Defective ther-

Check that the pilot flame impinges on the thermocouple. Clean and/or

stay lit after care-

mocouple.

adjust the pilot for maximum flame impingement.

fully following the

 

 

lighting instructions.

 

Ensure that the thermocouple connection at the gas valve is fully inserted

 

 

and tight (hand tighten plus 1/4 turn).

 

 

Disconnect the thermocouple from the valve, place one millivolt meter

 

 

lead wire on the tip of the thermocouple and the other meter lead wire on

 

 

the thermocouple copper lead. Start the pilot and hold the valve knob in. If

 

 

the millivolt reading is less than 15mV, replace the thermocouple.

 

b. Defective valve.

If the thermocouple is producing more than 15 millivolts, replace faulty

 

 

valve.

3. The pilot is

a. ON/OFF switch

Check the ON/OFF switch and wires for proper connections. Place the

burning, there is

or wires defective.

jumper wires across the terminals at the switch. If the burner comes on,

no burner flame,

 

replace the defective switch. If the switch is OK, place the jumper wires

the valve knob is

 

across the switch wires at the gas valve. If the burner comes on, the wires

in the ON position,

 

are faulty or connections are bad.

and the ON/OFF

 

 

b. Thermopile may

If the pilot flame is not close enough physically to the thermopile, adjust

switch is in the ON

not be generating

the pilot flame.

position.

sufficient millivolt-

 

 

 

 

age.

Be sure the wire connections from the thermopile at the gas valve termi-

 

 

nals are tight and that the thermopile is fully inserted into the pilot bracket.

 

 

Check the thermopile with a millivolt meter. Take the reading at TH-

 

 

TP&TP terminals of the gas valve. The meter should read 325 millivolts

 

 

minimum, while holding the valve knob depressed in the pilot position,

 

 

with the pilot lit, and the ON/OFF switch in the OFF position. Replace the

 

 

faulty thermopile if the reading is below the specified minimum.

 

 

With the pilot in the ON position, disconnect the thermopile leads from

 

 

the valve. Take a reading at the thermopile leads. The reading should be

 

 

325 millivolts minimum. Replace the thermopile if the reading is below the

 

 

minimum.

 

 

 