Heat & Glo LifeStyle SL-550TV-D 1Listing and Code Approvals, A.Appliance Certification, Models

Models: SL-750TV-D SL-950TV-IPI-D SL-550TV-D SL-550TV-IPI-D SL-750TV-IPI-D SL-950TV-D

1 54
Download 54 pages 51.66 Kb
Page 4
Image 4
1Listing and Code Approvals

1Listing and Code Approvals

A.Appliance Certification

MODELS: SL-550TV-D, SL-750TV-D, SL-950TV-D,

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: B-Vent Decorative

STANDARD: ANSI Z21.50-2002 • CGA2.2

This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Altitudes”.

This model (natural gas and propane) can be installed in a bedroom (in the United States) which has a total volume of unconfined space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/

NFPA54 (current edition), The Uniform Mechanical Code - (current edition), and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space.

This model (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat (Model WH-STAT) is installed with the unit. Consult local code authorities. Detailed installation instructions for Model WH-STAT are included with the kit.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

Heat & Glo Quality Systems registered by SGS ICS

B. Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

C. BTU Specifications

Model(s)

 

Maximum

Minimum

Orifice

 

Input BTU/h

Input BTU/h

Size

U.S. (0-2000 ft.) or Canada (2000-4500 ft.)

(DMS)

SL-550TV-D

US

21,000

12,000

44

 

 

 

 

SL-550TV-IPI-D

CAN

18,900

10,800

45

 

 

 

 

 

 

SL-550TV-D (LP)

US

20,000

N/A

54

 

 

 

 

SL-550TV-IPI-D (LP)

CAN

18,000

N/A

55

 

 

 

 

 

 

SL-750TV-D

US

23,000

16,000

42

 

 

 

 

SL-750TV-IPI-D

CAN

20,700

14,400

43

 

 

 

 

 

 

SL-750TV-D (LP)

US

23,000

N/A

53

 

 

 

 

SL-750TV-IPI-D (LP)

CAN

20,700

N/A

54

 

 

 

 

 

 

SL-950TV-D

US

30,000

21,000

36

 

 

 

 

SL-950TV-IPI-D

CAN

27,000

18,900

37

 

 

 

 

 

 

SL-950TV-D (LP)

US

30,000

21,000

51

 

 

 

 

SL-950TV-IPI-D (LP)

CAN

27,000

N/A

52

 

 

 

 

 

 

4

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07