E. Junction Box Installation

E. Junction Box Installation

If the box is being wired from the OUTSIDE of the appliance:

Remove the cover plate located on the outer shell right side (see Figure 10.4).

Install the supplied Romexconnector in the cover plate.

Feed the necessary length of wire through the connector.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box/recep- tacle to the outer shell, rotate the junction box/recep- tacle inward to disengage it from the outer shell (see Figure 10.4).

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Feed the necessary length of wire through the connector.

Make all necessary wire connections to the junction box/receptacle and reassemble the junction box/ receptacle to the outer shell.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

GRN wire

 

NOTE: Do NOT wire

Figure 10.4 Junction Box Detail

110VAC to wall switch.

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted

 

 

 

 

switch for use with a fan (See Figure 10.5):

 

 

 

 

The power supply for the appliance must

 

 

 

SWITCH

 

be brought into a switch box.

MINIMUM 14-3 AWG

 

 

 

 

 

WITH GROUND

 

 

 

• The power can then be supplied from the

 

 

Red

 

 

switch box to the appliance using a mini-

 

 

Black

Black

 

mum of 14-3 with ground wire.

 

 

White

White

 

 

 

Green

Green

At the switch box connect the black (hot)

JUNCTION BOX

 

Green

 

Red

Black White

 

 

wire and red (switch leg) wire to the wall

 

 

switch as shown.

 

 

 

POWER

 

 

 

 

SUPPLY WIRES

At the appliance connect the black (hot),

 

 

 

SWITCH BOX

 

white (neutral) and green (ground) wires

 

 

 

 

 

to the junction box as shown.

 

 

 

 

Add a 1/4 inch insulated female connector

 

 

 

 

 

to the red (switch leg) wire, route it through

Red

 

 

 

 

the knockout in the face of the junction box,

 

 

 

 

 

and connect to the top fan switch connector

 

 

 

 

 

(1/4 inch male) as shown.

Figure 10.5 Fan Control Switch Wiring

 

 

 