Heat & Glo LifeStyle SL-950TV-D Vent Information and Diagrams, A. Vent Guidelines, Models

Models: SL-750TV-D SL-950TV-IPI-D SL-550TV-D SL-550TV-IPI-D SL-750TV-IPI-D SL-950TV-D

1 54
Download 54 pages 51.66 Kb
Page 13
Image 13
5 Vent Information and Diagrams

5 Vent Information and Diagrams

A. Vent Guidelines

 

Rise to Run Ratio = 2:1

WARNING

 

Maximum Total Horizontal Run = 15 Feet

 

Minimum Total Vertical Rise = 9 Feet

Fire Risk.

 

Maximum Total Vertical Rise = 30 Feet

 

Maximum Number of Elbows: Two 900 or Four 450

Asphyxiation Risk.

 

 

 

This appliance requires the specified pipe for

 

operation.

 

 

• Incorrect pipe may cause spillage, condensation

MINIMUM CLEARANCES

and overheating.

 

 

ARE PER VENT

 

 

MANUFACTURER’S

These models require the following size B-vent double

SPECIFICATIONS

 

wall, or single wall rigid or flex vent pipe.

 

 

Models

Pipe Size

9 FEET

SL-550TV-D, SL-550TV-IPI-D

5 inches

MINIMUM

SL-750TV-D, SL-750TV-IPI-D

5 inches

 

SL-950TV-D, SL-950TV-IPI-D

6 inches

 

B-vent pipe MUST be used when the vent system is

VENT SUPPORTS ARE PER

within combustible construction.

 

VENT MANUFACTURER’S

 

 

SPECIFICATIONS

Single wall rigid or flexible vent may be used ONLY if the vent system is installed within non-combustible construction such as a masonry chimney.

Follow pipe manufacturer’s installation guidelines when installing the appliance.

WARNING

Figure 5.1

 

 

Fire Hazard.

 

 

 

Explosion Risk.

 

 

 

Asphyxiation Risk.

 

 

 

Do NOT connect this gas appliance to a

 

 

 

chimney flue serving a separate solid-fuel or

VENT SUPPORTS

 

 

gas burning appliance.

 

 

ARE PER VENT

 

 

• Vent this appliance directly outside.

MANUFACTURER'S

METAL

 

• Use separate vent system for this appliance.

SPECIFICATIONS.

PLUMBERS' STRAP

 

 

 

 

May impair safe operation of this appliance or

 

 

 

other appliances connected to the flue.

 

 

B. Vent System Configuration

MAXIMUM HORIZONTAL RUN IS 50%

 

 

OF VERTICAL. HORIZONTAL RUN

 

CAUTION

CANNOT BE MORE THAN 15 FT.

 

 

 

ALL vent configuration specifications MUST be followed.

 

 

This product is tested and listed to appliance and vent

 

 

 

manufacturer’s specifications.

 

 

• Appliance performance will suffer if specifications are not

 

 

 

followed.

Figure 5.2

 

 

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07