B. Constructing the Appliance Chase

B. Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.

Construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts in cold climates, the firestops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high temp caulk or stuffed with unfaced insulation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath to prevent conducting cold up into the room.

C. Clearances

WARNING

Fire Risk.

Odor Risk.

Install appliance on hard metal or wood surfaces

extending full width and depth of appliance.

Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.

Do NOT place furniture or any other combustible household objects within 36 inches of the appliance front.

C. Clearances WARNING

Fire Risk.

Construct chase to all clearance specifications in manual.

Locate and install appliance to all clearance

specifications in manual

Î

A

E

F

B

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

I

 

 

 

 

 

 

 

 

 

 

 

Models

A

B

C

D

E

F

G

H

I

J

SL-550TV-D

Inches

10

33

16-1/4

37

31

0

0

1/2

1/2

36

mm

254

838

413

940

787

0

0

13

13

914

 

SL-750TV-D

Inches

10

38-1/4

16-1/4

42

31

0

0

1/2

1/2

36

mm

254

971

413

1067

787

0

0

13

13

914

 

SL-950TV-D

Inches

10

42-1/4

16-1/4

49

31

0

0

1/2

1/2

36

mm

254

1073

413

1245

787

0

0

13

13

914

 

Figure 3.2 Clearances to Combustibles