Heat & Glo LifeStyle SL-550TV-IPI-D Framing and Clearances, A. Selecting Appliance Location

Models: SL-750TV-D SL-950TV-IPI-D SL-550TV-D SL-550TV-IPI-D SL-750TV-IPI-D SL-950TV-D

1 54
Download 54 pages 51.66 Kb
Page 9
Image 9
3 Framing and Clearances

3 Framing and Clearances

NOTE:

 

WARNING

Illustrations reflect typical installations and are FOR

 

 

DESIGN PURPOSES ONLY.

Fire Risk

Illustrations/diagrams are not drawn to scale.

Provide adequate clearance:

Actual installation may vary due to individual design

Around air openings

 

preference.

 

To combustibles

 

 

 

 

For service access

A. Selecting Appliance Location

Locate appliance away from traffic areas.

 

 

When selecting a location for your appliance it is important to

consider the required clearances to walls (see Figure 3.1). NOTE: For actual appliance dimensions refer to

Section 16.

A

 

F

 

TOP VENT

 

B

 

ALCOVE

D

INSTALLATION

A

 

B

 

C

 

TOP VENT

 

TOP VENT

A. Selecting Appliance LocationB Section 16.

E

Model

A

B

C

D

E

F

 

 

 

 

 

 

 

 

SL-550TV-D

Inches

41-1/2

37

58-3/4

 

16-1/4

1/2

 

 

 

 

 

 

 

Millimeters

1054

940

1492

 

413

13

 

 

 

 

 

 

 

36 Inches

 

 

 

Inches

45

42

63-3/4

16-1/4

1/2

SL-750TV-D

914 Millimeters

 

 

 

 

 

 

Millimeters

1143

1067

1619

Maximum

413

13

 

 

 

 

 

 

 

 

 

 

 

SL-950TV-D

Inches

50

49

70-3/4

 

16-1/4

1/2

 

 

 

 

 

 

 

Millimeters

1270

1245

1792

 

413

13

 

 

 

 

 

 

 

 

 

 

In addition to these framing dimensions, also reference the following sections:

Clearances and Mantel Projections (Sections 3.C and 3.D)

Vent Clearances and Framing (Section 6).

ÎFigure 3.1 Appliance Locations

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. J • 4/07

9

Page 9
Image 9
Heat & Glo LifeStyle SL-550TV-IPI-D, SL-950TV-IPI-D Framing and Clearances, A. Selecting Appliance Location, Section